Suppr超能文献

不同对映异构体农药在液相色谱-电喷雾电离-质谱中的响应。

Different responses of E:Z-isomers of pesticides in liquid chromatography-electrospray ionization-mass spectrometry.

机构信息

R&D, Okolab Gesellschaft für Umweltanalytik, A Member of the Japan Tobacco International Group of Companies, Hasnerstrasse 127, 1160 Vienna, Austria.

出版信息

J Mass Spectrom. 2010 Jul;45(7):715-21. doi: 10.1002/jms.1757.

Abstract

The mass spectrometric behavior of four pairs of stereoisomers was investigated by liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS). The E- and Z-isomers of the pesticides chlorfenvinphos, dimethomorph, mevinphos and phosphamidon-each with one double bond-were chosen for this study. The MS response of the individual isomers was investigated by infusing the isomers individually into the MS or after the separation of isomer mixtures via high-performance liquid chromatography (HPLC). In the case of dimethomorph, the same MS response was found for the two isomers. In contrast to that, the individual isomers of chlorfenvinphos, mevinphos and phosphamidon showed different MS response both in the single ion monitoring (SIM) mode in single quadrupole MS and multiple reaction monitoring (MRM) mode in tandem MS. The MS response of the isomers partly depends on (1) the declustering potential of the precursor ion in the SIM mode, (2) the selected transition and (3) the collision energy in the MRM mode. Consequently, quantification by summation of the peak areas of the isomers is inaccurate due to over- or underestimating of one of the stereoisomers. Accurate quantitative results can only be achieved when the compound-specific MS parameters are separately determined for each isomer. This can be done by using pure isomers or by the determination of the MS parameters after HPLC separation and the measurement of the actual isomer ratio with an independent technique.

摘要

采用液相色谱-电喷雾电离-质谱(LC-ESI-MS)研究了四对立体异构体的质谱行为。本研究选择了具有一个双键的农药氯芬磷、二甲戊灵、硫丹和磷酰胺的 E-和 Z-异构体。通过将异构体分别注入 MS 或通过高效液相色谱(HPLC)分离异构体混合物后,研究了各个异构体的 MS 响应。在二甲戊灵的情况下,两种异构体的 MS 响应相同。与二甲戊灵不同,氯芬磷、硫丹和磷酰胺的各个异构体在单四极杆 MS 的单离子监测(SIM)模式和串联 MS 的多重反应监测(MRM)模式下均表现出不同的 MS 响应。异构体的 MS 响应部分取决于(1)SIM 模式下前体离子的去簇电位,(2)所选跃迁和(3)MRM 模式下的碰撞能量。因此,由于对一个立体异构体的高估或低估,通过对异构体峰面积的总和进行定量是不准确的。只有当分别为每个异构体确定特定化合物的 MS 参数时,才能获得准确的定量结果。这可以通过使用纯异构体或通过在 HPLC 分离后确定 MS 参数并使用独立技术测量实际异构体比来实现。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验