To investigate the effectiveness of a traditional flip-chart optotype test, the Sheridan Gardiner test (SGT), in measuring visual acuity and detecting amblyopia, compared with a free, computer-based test (CBT), LazyeyeTest.org.
Prospective, masked, cross-over study.
Seventy kindergarten-aged children from a downtown Toronto elementary school enrolled in the Kids2See vision screening program.
Visual acuity in the children was measured monocularly using both tests. The visual acuity results, number of referrals, and outcomes of referrals were compared, as was the usability from the perspective of the child and the vision screener.
The children were more likely to score low visual acuity values with the CBT, a result predicted by the existence of crowding bars on the CBT's optotypes. The CBT referred an extra 5 children than the SGT, and of the 4 who saw an ophthalmologist 2 had amblyopia. The SGT referred one child not referred by the CBT. The Cohen's kappa coefficient was 0.67 and the difference in referral rates was not significant (p = 0.13). Relative to the SGT, the sensitivity of the CBT was 88%, specificity was 92%, positive predictive value was 58%, and negative predictive value was 98%. The CBT appeared to be easier and more efficient to administer, more stimulating, and was preferred by the children.
Replacing the SGT with LazyeyeTest.org would increase the efficiency and likely the sensitivity of amblyopia screening. Further research is warranted to confirm the outcomes and to determine if the CBT can be administered accurately by lay screeners.
研究一种传统的翻页图表视力测试(Sheridan Gardiner 测试,SGT)与免费的计算机测试(LazyeyeTest.org)在测量视力和发现弱视方面的有效性。
前瞻性、盲法、交叉研究。
70 名来自多伦多市中心一所小学的幼儿园儿童参加了 Kids2See 视力筛查计划。
使用两种测试方法对儿童进行单眼视力测量。比较了视力结果、转诊数量和转诊结果,以及从儿童和视力筛查员的角度来看的可用性。
儿童使用 CBT 测试更有可能获得低视力值,这是 CBT 测试中的拥挤条预测的结果。CBT 比 SGT 多转诊了 5 名儿童,在接受眼科检查的 4 名儿童中,有 2 名患有弱视。SGT 转诊了一名 CBT 未转诊的儿童。Cohen's kappa 系数为 0.67,转诊率差异无统计学意义(p=0.13)。与 SGT 相比,CBT 的敏感性为 88%,特异性为 92%,阳性预测值为 58%,阴性预测值为 98%。CBT 似乎更容易管理、更有效率、更具刺激性,且儿童更喜欢。
用 LazyeyeTest.org 替代 SGT 将提高弱视筛查的效率和敏感性。需要进一步研究以确认结果,并确定 CBT 是否可以由非专业人员准确进行管理。