Efficiency of an enclosed afferent reservoir breathing system during controlled ventilation.

作者信息

Droppert P M, Meakin G, Beatty P C, Mortimer A J, Healy T E

机构信息

University Department of Anaesthesia, Withington Hospital, Manchester.

出版信息

Br J Anaesth. 1991 Jun;66(6):638-42. doi: 10.1093/bja/66.6.638.

DOI:10.1093/bja/66.6.638
PMID:2064876
Abstract

We describe an enclosed afferent reservoir (EAR) breathing system developed by Ohmeda and designed to operate efficiently in spontaneous and controlled ventilation. The efficiency of the system was evaluated by calculating the fractional utilization of fresh gas in 10 ASA I-III patients during anaesthesia with controlled ventilation. Maximum efficiency occurred when the minute ventilation to fresh gas flow ratio was greater than 1.5. Under these conditions, fractional utilization was relatively constant with a value of 0.73 (95% confidence interval 0.69-0.78). The minimum fresh gas flow for use during controlled ventilation was determined in another eight ASA I-III patients when the minute volume to fresh gas ratio was greater than 1.5. In view of an increased arterial to end-tidal carbon dioxide partial pressure difference in patients in the first part of the study (1.03 kPa), normocapnia was defined as an end-tidal carbon dioxide partial pressure of 4.3 kPa. Normocapnia was achieved with a mean fresh gas flow of 66 ml kg(-1) min(-1), while 70 ml kg(-1) min(-1) produced mild hypocapnia.

摘要

相似文献

1
Efficiency of an enclosed afferent reservoir breathing system during controlled ventilation.
Br J Anaesth. 1991 Jun;66(6):638-42. doi: 10.1093/bja/66.6.638.
2
Fresh gas requirements of an enclosed afferent reservoir breathing system during controlled ventilation in children.
Br J Anaesth. 1992 Jan;68(1):43-7. doi: 10.1093/bja/68.1.43.
3
Physical characteristics of an enclosed afferent reservoir breathing system.封闭式传入储气囊呼吸系统的物理特性。
Br J Anaesth. 1992 Jun;68(6):625-9. doi: 10.1093/bja/68.6.625.
4
Preliminary evaluation of the Enclosed Magill Breathing System.封闭式马吉尔呼吸系统的初步评估。
Br J Anaesth. 1989 Feb;62(2):144-9. doi: 10.1093/bja/62.2.144.
5
Determination of the onset of rebreathing in an enclosed afferent reservoir breathing system in anaesthetized, spontaneously breathing adults: a comparison of three methods.麻醉状态下自主呼吸成年患者封闭传入贮气囊呼吸系统中再呼吸起始点的测定:三种方法的比较
Eur J Anaesthesiol. 1994 May;11(3):187-91.
6
A clinical determination of optimal fresh gas flow in a baby EAR circuit.婴儿EAR回路中最佳新鲜气体流量的临床测定。
J Med Assoc Thai. 2009 May;92(5):667-71.
7
Enclosed afferent reservoir breathing systems. Description and clinical evaluation.封闭式输入型贮气囊呼吸系统。描述与临床评估。
Br J Anaesth. 1988 Mar;60(4):469-75. doi: 10.1093/bja/60.4.469.
8
Fresh gas requirements of an enclosed afferent reservoir breathing system in anaesthetized, spontaneously ventilating children.麻醉状态下自主呼吸儿童的封闭式输入贮气囊呼吸系统的新鲜气体需求量
Br J Anaesth. 1992 Apr;68(4):333-7. doi: 10.1093/bja/68.4.333.
9
Comparison of minimal fresh gas requirements of baby enclosed afferent reservoir and Jackson Rees anesthetic circuit for general anesthesia in spontaneously breathing children.婴儿封闭式输入贮气囊与杰克逊·里斯麻醉回路用于自主呼吸儿童全身麻醉时最低新鲜气体需求量的比较。
J Med Assoc Thai. 2014 Nov;97(11):1171-6.
10
Fractional delivery of fresh gas: a new index of the efficiency of semi-closed breathing systems.新鲜气体的分次输送:半封闭式呼吸系统效率的新指标。
Br J Anaesth. 1992 Nov;69(5):474-7. doi: 10.1093/bja/69.5.474.