OBJECTIVE

The aim of this study was to evaluate the intraobserver and interobserver reproducibility of measurements, obtained from stored ultrasound volumes, related to fetal head progression in the birth canal.

METHODS

From January to September 2009, serial ultrasound volumes were obtained from women in labor, stored and separately evaluated by two different operators using the SonoVCAD™ labor software. Volumes were aligned using the pubic bone and the urethra as references. In the sagittal plane of the pelvis, the following data were calculated: head progression distance (the distance between the infrapubic line and the lowest part of the fetal skull), head direction (the angle between the infrapubic line and the major longitudinal axis of the fetal head) and head progression angle (the angle between the longitudinal axis of the pubic bone and a line joining the lowest edge of the pubis to the lowest convexity of the fetal skull). In the transverse plane, the angle formed by the midline with the anteroposterior axis of the maternal pelvis (midline angle) was also measured. For each measurement, intraobserver and interobserver reproducibility was determined.

RESULTS

We analyzed 30 ultrasound volumes. For all parameters, interobserver variation was significantly higher than intraobserver variation. Reproducibility was good for all parameters, except for the midline angle. Among the different ultrasound measurements, the progression angle presented the highest reproducibility.

CONCLUSIONS

Measurements obtained from stored ultrasound volumes to assess fetal head progression in the second stage of labor have good reproducibility, with progression distance and progression angle being the most reproducible parameters.

摘要

目的

本研究旨在评估通过存储的超声体积获得的与胎儿头部在产道中进展相关的测量值的观察者内和观察者间可重复性。

方法

2009 年 1 月至 9 月,对分娩中的女性连续获取超声体积,使用 SonoVCAD™ 分娩软件由两位不同的操作员对其进行存储并分别评估。使用耻骨和尿道作为参考来对齐体积。在骨盆矢状面中,计算以下数据:头部进展距离(耻骨线与胎儿颅骨最低点之间的距离)、头部方向(耻骨线与胎儿头部的主要纵轴之间的角度)和头部进展角度(耻骨的纵轴与连接耻骨最低点到胎儿颅骨最低点的凸面的线之间的角度)。在横切面中,还测量了中线与母体骨盆前后轴之间形成的角度(中线角度)。对于每个测量值,确定了观察者内和观察者间的可重复性。

结果

我们分析了 30 个超声体积。对于所有参数,观察者间的变异性明显高于观察者内的变异性。除中线角度外,所有参数的可重复性均良好。在不同的超声测量中,进展角度的可重复性最高。

结论

从存储的超声体积中获得的评估第二产程中胎儿头部进展的测量值具有良好的可重复性,其中进展距离和进展角度是最可重复的参数。