Suppr超能文献

经阴道胆囊切除术应用原型柔性夹闭器。

Transvaginal cholecystectomy by using a prototype flexible clip applier.

机构信息

Department of General Surgery, University of Missouri, Columbia, Missouri 65212, USA.

出版信息

Gastrointest Endosc. 2010 Aug;72(2):351-7. doi: 10.1016/j.gie.2010.02.050.

Abstract

BACKGROUND

Currently, no endoscopic clips have been proven to be effective in ligating the cystic duct in natural orifice transluminal endoscopic surgery (NOTES) hybrid cholecystectomy.

OBJECTIVE

To determine the safety and feasibility of a prototype endoscopic flexible clip applier, which is the only flexible device that deploys a zero-gap clip.

DESIGN

Pilot study in a survival porcine model. Necropsy was performed at 2 weeks postprocedure.

SETTING

University of Missouri animal laboratory, Columbia, Missouri.

INTERVENTION

Transvaginal cholecystectomy was performed on 6 survival pigs using the NOTES Toolbox 1.0.

MAIN OUTCOME MEASUREMENTS

Safety and feasibility of the described instrument. Investigators were asked to fill out a standardized, blinded questionnaire on the ease of use and functionality of the flexible clip applier.

RESULTS

Clipping of the cystic duct was achieved with the flexible clip applier in all 6 pigs. The mean time for completion of clipping of the cystic duct was 9 minutes. Multiple attempts were required to successfully fire the clip in 2 of 6 pigs. We were unable to visualize the tip of the clip before deployment. Difficulty releasing the clip from the applier once fired and challenges in clip loading were encountered. The clips were visualized in place at necropsy, with no bile leakage, evidence of infection, or injury to surrounding structures seen in any cases.

LIMITATIONS

Preclinical animal model.

CONCLUSION

The prototype flexible clip applier showed adequate safety and was feasible in clipping the cystic duct in all animals. Design efforts to improve clip visualization, loading, and release are underway.

摘要

背景

目前,尚无内镜夹被证明可有效结扎经自然腔道内镜外科(NOTES)杂交胆囊切除术的胆囊管。

目的

确定原型内镜柔性夹闭器的安全性和可行性,这是唯一部署零间隙夹的柔性装置。

设计

生存猪模型的初步研究。术后 2 周进行尸检。

地点

密苏里大学动物实验室,密苏里州哥伦比亚市。

干预

6 只存活猪通过NOTES 工具箱 1.0 行经阴道胆囊切除术。

主要观察指标

描述器械的安全性和可行性。研究人员被要求填写一份标准化的、盲法的问卷,评估柔性夹闭器的易用性和功能。

结果

在所有 6 只猪中,柔性夹闭器都成功夹闭了胆囊管。夹闭胆囊管的平均时间为 9 分钟。在 6 只猪中的 2 只中,需要多次尝试才能成功发射夹。在发射前,我们无法看到夹的尖端。一旦发射后,从夹闭器上释放夹存在困难,夹的装载也存在挑战。在尸检时,可见夹在适当的位置,没有胆汁泄漏、感染证据或周围结构损伤。

局限性

临床前动物模型。

结论

原型柔性夹闭器在夹闭所有动物的胆囊管时显示出足够的安全性和可行性。正在进行设计改进,以提高夹的可视化、装载和释放。