McDermott Hugh, Henshall Katherine
Department of Otolaryngology, University of Melbourne, Australia.
J Am Acad Audiol. 2010 Jun;21(6):380-9. doi: 10.3766/jaaa.21.6.3.
The number of cochlear implant (CI) recipients who have usable acoustic hearing in at least one ear is continuing to grow. Many such CI users gain perceptual benefits from the simultaneous use of acoustic and electric hearing. In particular, it has been shown previously that use of an acoustic hearing aid (HA) with a CI can often improve speech understanding in noise.
To determine whether the application of frequency compression in an HA would provide perceptual benefits to CI recipients with usable acoustic hearing, either when used in combination with the CI or when the HA was used by itself.
A repeated-measures experimental design was used to evaluate the effects on speech perception of using a CI either alone or simultaneously with an HA that had frequency compression either enabled or disabled.
Eight adult CI recipients who were successful users of acoustic hearing aids in their nonimplanted ears participated as subjects.
The speech perception of each subject was assessed in seven conditions. These required each subject to listen with (1) their own HA alone; (2) the Phonak Naida HA with frequency compression (SoundRecover) enabled; (3) the Naida with SoundRecover disabled; (4) their CI alone; (5) their CI and their own HA; (6) their CI and the Naida with SoundRecover enabled; and (7) their CI and the Naida with SoundRecover disabled. Test sessions were scheduled over a period of about 10 wk. During part of that time, the subjects were asked to use the Phonak Naida HA with their CIs in place of their own HAs.
The speech perception tests included measures of consonant identification from a closed set of 12 items presented in quiet, and measures of sentence understanding in babble noise. The speech materials were presented at an average level of 60 dB SPL from a loudspeaker.
Speech perception was better, on average, in all conditions that included use of the CI in comparison with any condition in which only an HA was used. For example, consonant recognition improved by approximately 50 percentage points, on average, between the HA-alone listening conditions and the CI-alone condition. There were no statistically significant score differences between conditions with SoundRecover enabled and disabled. There was a small but significant improvement in the average signal-to-noise ratio (SNR) required to understand 50% of the words in the sentences presented in noise when an HA was used simultaneously with the CI.
Although each of these CI users readily accepted the Phonak Naida HA with SoundRecover frequency compression, no benefits related specifically to the use of SoundRecover were found in the particular tests of speech understanding applied in this study. The relatively high levels of perceptual performance attained by these subjects with use of a CI by itself are consistent with the finding that the addition of an HA provided little further benefit. However, the use of an HA with the CI did provide better performance than the CI alone for understanding sentences in noise.
至少有一只耳朵具有可用听觉的人工耳蜗(CI)植入者数量持续增加。许多此类CI使用者通过同时使用听觉和电听觉获得了感知益处。特别是,先前已经表明,将助听器(HA)与CI同时使用通常可以改善噪声环境下的言语理解。
确定在HA中应用频率压缩是否会为具有可用听觉的CI植入者带来感知益处,无论是与CI联合使用还是单独使用HA时。
采用重复测量实验设计来评估单独使用CI或与启用或禁用频率压缩的HA同时使用时对言语感知的影响。
八名成年CI植入者作为受试者参与研究,他们在未植入的耳朵中成功使用了助听器。
在七种条件下评估每个受试者的言语感知。这些条件要求每个受试者分别使用(1)他们自己的HA;(2)启用频率压缩(SoundRecover)的峰力奈达HA;(3)禁用SoundRecover的奈达HA;(4)单独使用CI;(5)CI和他们自己的HA;(6)CI和启用SoundRecover的奈达HA;(7)CI和禁用SoundRecover的奈达HA。测试环节安排在大约10周的时间内。在此期间的部分时间里,要求受试者使用峰力奈达HA与CI配合,取代他们自己的HA。
言语感知测试包括在安静环境中对12个封闭项目进行辅音识别的测量以及在嘈杂环境中对句子理解的测量。言语材料通过扬声器以平均60 dB SPL的水平呈现。
与仅使用HA的任何条件相比,在所有包括使用CI的条件下,言语感知平均更好。例如,在单独使用HA的聆听条件和单独使用CI的条件之间平均而言,辅音识别提高了约50个百分点。启用和禁用SoundRecover的条件之间在分数上没有统计学上的显著差异。当HA与CI同时使用时,在嘈杂环境中理解句子中50%的单词所需的平均信噪比(SNR)有小幅但显著的改善。
尽管这些CI使用者中的每一个都欣然接受了具有SoundRecover频率压缩功能的峰力奈达HA,但在本研究应用的特定言语理解测试中未发现与使用SoundRecover相关的益处。这些受试者单独使用CI时获得的相对较高水平的感知表现与添加HA几乎没有进一步益处的发现一致。然而,HA与CI一起使用在理解嘈杂环境中的句子方面确实比单独使用CI表现更好。