Hesselbacher K H, Anders K, Frohn A
Appl Opt. 1991 Nov 20;30(33):4930-5. doi: 10.1364/AO.30.004930.
A special sizing technique is applied to measuring the diameter of monosized droplet streams that are used for investigation of fuel droplets in enginelike conditions. For these experiments the droplet diameter must be known precisely. The sizing technique used is based on the evaluation of the fringe spacing of scattered light in the forward direction. This technique is independent of the intensity of the incident light. No absolute intensities need to be measured. The droplets are exposed to a focused laser beam. Therefore the frequently used assumption of plane wave fronts is not fulfilled. Elaborate experiments have been carried out to study the influence of a Gaussian intensity distribution of the laser beam on the accuracy of the sizing technique. It has been shown that the droplet diameter can be measured to an accuracy of better than 2% even if the droplet is illuminated by a Gaussian beam for a droplet diameter that is smaller than the beam diameter.
一种特殊的测量技术被应用于测量单尺寸液滴流的直径,这些液滴流用于在类似发动机的条件下研究燃料液滴。对于这些实验,必须精确知道液滴直径。所使用的测量技术基于对向前散射光条纹间距的评估。该技术与入射光强度无关。无需测量绝对强度。液滴暴露于聚焦激光束下。因此,常用的平面波前假设不成立。已经进行了详细的实验来研究激光束的高斯强度分布对测量技术精度的影响。结果表明,即使对于直径小于光束直径的液滴,当液滴由高斯光束照射时,液滴直径也能测量到优于2%的精度。