人胫骨前肌电诱发肌电信号的可重复性。

Repeatability of electrically-evoked myoelectric signals in the human tibialis anterior muscle.

机构信息

NeuroMuscular Research Center and Department of Biomedical Engineering, Boston University, Boston, U.S.A.; Politecnico di Torino, Torino, Italy.

出版信息

J Electromyogr Kinesiol. 1995 Jun;5(2):67-80. doi: 10.1016/1050-6411(94)00004-6.

Abstract

The reproducibility of surface myoelectric signal measurements is of paramount importance for clinical applications of electromyography (EMG) techniques. The repeatability of electrically-evoked myoelectric signal shape (M-wave) as well as spectral and amplitude parameters, conduction velocity and elicited torque was tested, in isometric conditions, on the tibialis anterior muscle of 10 normal subjects. Contractions were elicited by stimulation of the main muscle motor point and repeated after removal and replacement of the stimulation and detection electrodes in the same carefully marked locations. This protocol was repeated five times on each subject on five different days. The test-retest Pearson correlation coefficient, the paired t test and analysis of variance (ANOVA) were used to quantify repeatability and estimate the fraction of variance due to repeated trials within experiments, repeated experiments within subjects and inter-subject variability. Results indicate that parameters of spectral variables are more repeatable than those of amplitude variables. Elicited torque and conduction velocity show the lowest repeatability. The intra-class correlation coefficient ranged from 87.9% for the initial value of median frequency to 11.5% for the initial value of conduction velocity. Fatigue indices based on the time course of the myoelectric signal variables showed even lower values of this coefficient. It is concluded that: (a) initial values and fatigue indices based on spectral variables are more repeatable than those based on amplitude variables; (b) the repeatability of conduction velocity and torque is very poor; (c) M-wave shape, rather than amplitude or width, seems to be a characteristic of individual muscles; and (d) electrode location is a critical issue in the study of M-waves elicited by stimulation of a muscle motor point. The methodology for estimation of muscle fibre conduction velocity must be refined and the characterization of evoked responses must be improved to allow widespread clinical applications.

摘要

表面肌电信号测量的可重复性对于肌电图(EMG)技术的临床应用至关重要。在等长条件下,对 10 名正常受试者的胫骨前肌进行了电诱发肌电信号形状(M 波)以及频谱和幅度参数、传导速度和诱发扭矩的重复性测试。通过刺激主要肌肉运动点来引发收缩,并在相同的精心标记位置上移除和更换刺激和检测电极后重复测试。每位受试者在 5 天内重复进行 5 次测试。使用测试-再测试 Pearson 相关系数、配对 t 检验和方差分析(ANOVA)来量化重复性,并估计实验内重复试验、受试者内重复试验和受试者间变异性引起的方差分数。结果表明,频谱变量的参数比幅度变量的参数更具重复性。诱发扭矩和传导速度的重复性最低。组内相关系数范围从中频初始值的 87.9%到传导速度初始值的 11.5%。基于肌电信号变量时间过程的疲劳指数显示出该系数的更低值。结论是:(a)基于频谱变量的初始值和疲劳指数比基于幅度变量的更具重复性;(b)传导速度和扭矩的重复性非常差;(c)M 波形状,而不是幅度或宽度,似乎是个体肌肉的特征;(d)在研究通过刺激肌肉运动点引发的 M 波时,电极位置是一个关键问题。估计肌纤维传导速度的方法学必须得到改进,并且必须改进诱发反应的特征化,以允许广泛的临床应用。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验