Suppr超能文献

用于树脂粘结铸造修复体的镍铬基合金电解蚀刻深度的评估。

Evaluation of the electrolytic etching depth of a nickel-chromium base alloy used in resin-bonded cast restorations.

作者信息

Schäffer H, Piffer A

机构信息

Department of Restorative Dentistry, University of Innsbruck, School of Dentistry, Austria.

出版信息

J Prosthet Dent. 1990 Dec;64(6):680-3. doi: 10.1016/0022-3913(90)90295-n.

Abstract

This study examined the relation of the electrolytic etching depth of a nickel-chromium base alloy to the etching time. Cast samples (22 mm long, 4 mm wide, 1.5 mm thick) were etched in the Eltrokor etching unit, using Korolyt A as the etching solution with a constant current density of 400 mA/cm2. On each sample an approximately 3 mm long area was etched for 5, 7, 9, and 11 minutes. Between each etched area, a field of approximately 2 mm long remained unetched. The surface of each sample was scanned with a profilometer. The distance of the compensation plane of the scanned etched profile to the unetched areas was then measured for each etching time. The average etched depth with an etching time of 5 minutes is 30.4 microns (SD 2.39); with a time of 7 minutes the depth is 44 microns (SD 3.49); with a time of 9 minutes the depth is 59.8 microns (SD 4.10); and with an etching time of 11 minutes the depth is 72.9 microns (SD 2.94). Taking the average of all etching depths per etching time, the average loss of substance is 6.409 microns per minute etching time.

摘要

本研究考察了镍铬基合金的电解蚀刻深度与蚀刻时间的关系。铸造样品(长22毫米、宽4毫米、厚1.5毫米)在Eltrokor蚀刻装置中蚀刻,使用Korolyt A作为蚀刻溶液,恒定电流密度为400毫安/平方厘米。在每个样品上,一个约3毫米长的区域分别蚀刻5、7、9和11分钟。在每个蚀刻区域之间,有一个约2毫米长的区域保持未蚀刻。用轮廓仪扫描每个样品的表面。然后针对每个蚀刻时间测量扫描的蚀刻轮廓的补偿平面到未蚀刻区域的距离。蚀刻时间为5分钟时的平均蚀刻深度为30.4微米(标准差2.39);7分钟时深度为44微米(标准差3.49);9分钟时深度为59.8微米(标准差4.10);11分钟时深度为72.9微米(标准差2.94)。以每个蚀刻时间的所有蚀刻深度的平均值计算,每分钟蚀刻时间的平均物质损失为6.409微米。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验