Abstract

Endobutton (Arthrex, Naples, FL) fixation of distal biceps rupture with interference screw fixation provides for a secure repair, allowing for early motion. We present a case in which Endobutton fixation failed with a loose interference screw, rendering the distal biceps attachment incompetent. Revision surgery with an extensile approach, mobilization of the biceps, and repeat Endobutton fixation at a more distal site provided a secure fixation with an excellent clinical outcome. An understanding of the mechanism of failure might allow surgeons to perform this procedure with a lower incidence of complications.

摘要

使用带袢纽扣(Arthrex公司,佛罗里达州那不勒斯)结合干涉螺钉固定修复肱二头肌远端断裂可实现牢固修复,允许早期活动。我们报告一例病例,其中带袢纽扣固定因干涉螺钉松动而失败,导致肱二头肌远端附着处功能不全。采用扩大入路进行翻修手术,游离肱二头肌,并在更远端部位再次使用带袢纽扣固定,实现了牢固固定,临床效果极佳。了解失败机制可能有助于外科医生降低该手术的并发症发生率。