通过Theraflex MB血浆系统制备的亚甲蓝处理血浆的凝血酶生成能力。

Thrombin Generation Capacity of Methylene Blue-Treated Plasma Prepared by the Theraflex MB Plasma System.

作者信息

Gravemann Ute, Kusch Manuela, Koenig Herbert, Mohr Harald, Mueller Thomas H

机构信息

DRK-Blutspendedienst NSTOB, Institut Springe, Langen, Germany.

出版信息

Transfus Med Hemother. 2009;36(2):122-127. doi: 10.1159/000202413. Epub 2009 Mar 4.

Abstract

BACKGROUND

Methylene blue (MB) / light treatment is a well-known procedure for the inactivation of pathogens in fresh frozen plasma (FFP). Aim of the current study was to investigate the thrombin generation (TG) characteristics and quality of MB plasma prepared by the Theraflex MB Plasma System. METHODS: Single donor plasma units (n = 18) were MB/light-treated, with sampling before and after processing. Preparation included leukocyte depletion, addition of MB pill prior to illumination, and depletion of MB and photoproducts by filtration. Different plasma parameters and TG were measured. TG additionally was determined in solvent/detergent plasma (n = 8). RESULTS: MB/light treatment significantly affected factors V, VIII and XI, which were decreased by 9-18%. While the antigen level was not affected, fibrinogen according to Clauss was decreased by 7%, correlating with a 12% prolongation of TT and RT. The total amount of free thrombin generated, given as 'area under the curve' (AUC), was comparable for untreated (93 +/- 18% of normal plasma) and MB/light-treated plasma (95 +/- 20%). Also peak thrombin concentration was not significantly affected by treatment (94 +/- 11% (untreated) vs. 96 +/- 12% (treated)). The 'time to peak' value (TTP) was 105% of normal plasma for untreated FFP and 89% for MB-treated plasma. CONCLUSION: For plasma treated with the Theraflex MB Plasma System no profound influence of MB/ light treatment on the characteristics of thrombin generation was detected. In concordance with data from the literature, coagulation factors V, VIII and XI were decreased due to MB/ light treatment. Decrease was less than 20%.

摘要

背景

亚甲蓝(MB)/光照处理是一种使新鲜冰冻血浆(FFP)中的病原体失活的知名方法。本研究的目的是调查通过Theraflex MB血浆系统制备的MB血浆的凝血酶生成(TG)特征和质量。方法:对单个供体的血浆单位(n = 18)进行MB/光照处理,并在处理前后进行采样。制备过程包括白细胞去除、光照前添加MB药丸,以及通过过滤去除MB和光产物。测量不同的血浆参数和TG。还在溶剂/去污剂血浆(n = 8)中测定TG。结果:MB/光照处理显著影响因子V、VIII和XI,其水平降低了9 - 18%。虽然抗原水平未受影响,但根据克劳斯法测定的纤维蛋白原降低了7%,与凝血酶时间(TT)和凝血酶原时间(RT)延长12%相关。以“曲线下面积”(AUC)表示的游离凝血酶生成总量,未处理血浆(正常血浆的93±18%)和MB/光照处理血浆(95±20%)相当。处理对凝血酶峰值浓度也无显著影响(未处理为94±11%,处理后为96±12%)。未处理FFP的“达峰时间”值(TTP)为正常血浆的105%,MB处理血浆为89%。结论:对于用Theraflex MB血浆系统处理的血浆,未检测到MB/光照处理对凝血酶生成特征有深远影响。与文献数据一致,由于MB/光照处理,凝血因子V、VIII和XI降低。降低幅度小于20%。

相似文献

本文引用的文献

1
The dynamics of clot formation in fresh-frozen plasma.新鲜冰冻血浆中凝块形成的动力学
Vox Sang. 2008 May;94(4):306-14. doi: 10.1111/j.1423-0410.2008.01037.x. Epub 2008 Feb 5.
6
Caution in the interpretation of continuous thrombin generation assays.连续凝血酶生成试验解读时需谨慎。
J Thromb Haemost. 2007 May;5(5):1084-5; author reply 1085-7. doi: 10.1111/j.1538-7836.2007.02512.x. Epub 2007 Mar 12.
7
Thrombin generation and fibrin clot structure.凝血酶生成与纤维蛋白凝块结构。
Blood Rev. 2007 May;21(3):131-42. doi: 10.1016/j.blre.2006.11.001. Epub 2007 Jan 8.