We evaluated direct low density lipoprotein (LDL) cholesterol (C) and high density lipoprotein (HDL) cholesterol (C) versus standard methods using fasting plasma samples from participants in cycle 6 of the Framingham Offspring Study.
Direct LDL-C and HDL-C measurements were performed on fasting plasma from male (1335 controls, 173 CHD cases) and female (1606 controls, 74 cases) participants, and compared with LDL-C, as calculated with the Friedewald formula, and HDL-C, as measured after dextran-Mg(2+) precipitation.
Values for direct LDL-C and HDL-C correlated well with standard methods (both about r(2)=0.94, p<0.001) with similar absolute values. Biases of >10% were present for 7.7% of samples for LDL-C, while for HDL-C this value was 8.5%. Despite higher use of cholesterol-lowering medication in CHD cases, calculated or direct LDL-C values were still well above recommended values [<2.6 mmol/L (100 mg/dL)] in CHD cases, especially in females.
Direct assays for both LDL-C and HDL-C provide an acceptable guide for lipid treatment. In Framingham Offspring Study participants most CHD cases had LDL-C levels above the recommended target.
我们评估了直接低密度脂蛋白(LDL)胆固醇(C)和高密度脂蛋白(HDL)胆固醇(C)与使用弗雷明汉后代研究第 6 周期参与者的空腹血浆样本的标准方法。
对男性(1335 名对照者,173 名 CHD 病例)和女性(1606 名对照者,74 名病例)参与者的空腹血浆进行直接 LDL-C 和 HDL-C 测量,并与 LDL-C(用 Friedewald 公式计算)和 HDL-C(用葡聚糖-Mg(2+)沉淀后测量)进行比较。
直接 LDL-C 和 HDL-C 值与标准方法相关性良好(均约 r(2)=0.94,p<0.001),绝对值相似。LDL-C 有 7.7%的样本偏差>10%,而 HDL-C 为 8.5%。尽管 CHD 病例中使用了更多的降胆固醇药物,但计算或直接 LDL-C 值仍远高于推荐值[<2.6 mmol/L(100 mg/dL)],尤其是女性。
直接 LDL-C 和 HDL-C 测定值为脂质治疗提供了可接受的指导。在弗雷明汉后代研究参与者中,大多数 CHD 病例的 LDL-C 水平高于推荐目标。