Department of Biophysics, Faculty of Science, Cairo University, Giza, Egypt.
Med Phys. 2010 Aug;37(8):4257-65. doi: 10.1118/1.3465046.
The evaluation of the diagnostic capability of easy to measure x-ray scattering profile characterization parameters for the detection of breast cancer in excised samples. The selected parameters are the full width at half maximum (FWHM) and area under the x-ray scattering profile of breast tissue in addition to the ratio of scattering intensities (I2/I1%) at 1.6 nm(-1) to that at 1.1 nm(-1) (corresponding to scattering from soft and adipose tissues, respectively).
A histopathologist is asked to classify 36 excised breast tissue samples into healthy or malignant. A conventional x-ray diffractometer is used to acquire the scattering profiles of the investigated samples. The values of three profile characterization parameters are calculated and the diagnostic capability of each is evaluated by determining the optimal cutoffs of scatter diagrams, calculating the diagnostic indices, and plotting the receiver operating characteristic (ROC) curves.
At the calculated optimal cutoff for each of the examined parameters, the sensitivity ranged from 78% (for area under curve) up to 94% (for FWHM), the specificity ranged from 94% [for I2/I1% and area under curve] up to 100% (for FWHM), and the diagnostic accuracy ranged from 86% (for area under curve) up to 97% (for FWHM). The area under the ROC curves is greater than 0.95 for all of the investigated parameters, reflecting a highly accurate diagnostic performance.
The discussed tests offered a means to quantitatively evaluate the performance of the suggested breast tissue x-ray scattering characterization parameters. The performance results are promising, indicating that the evaluated parameters would be considered a tool for fast, on spot probing of breast cancer in excised tissue samples.
评估易于测量的 X 射线散射谱特征参数在检测切除样本中的乳腺癌的诊断能力。所选参数除了散射强度比(I2/I1%)在 1.6nm-1 和 1.1nm-1 处(分别对应于软组织和脂肪组织的散射)之外,还包括全宽半最大值(FWHM)和乳房组织 X 射线散射谱的面积。
要求组织病理学家将 36 个切除的乳房组织样本分为健康或恶性。使用常规 X 射线衍射仪获取研究样本的散射谱。计算三个谱特征参数的值,并通过确定散点图的最佳截止值、计算诊断指数和绘制接收者操作特征(ROC)曲线来评估每个参数的诊断能力。
在所计算的每个检查参数的最佳截止值处,灵敏度从 78%(曲线下面积)到 94%(FWHM)不等,特异性从 94%[I2/I1%和曲线下面积]到 100%(FWHM)不等,诊断准确性从 86%(曲线下面积)到 97%(FWHM)不等。所有研究参数的 ROC 曲线下面积均大于 0.95,反映出高度准确的诊断性能。
讨论的测试提供了一种定量评估所建议的乳房组织 X 射线散射特征参数性能的方法。性能结果很有希望,表明所评估的参数将被视为快速、现场探测切除组织样本中乳腺癌的工具。