Gait Posture. 2010 Oct;32(4):619-26. doi: 10.1016/j.gaitpost.2010.09.004.
The objective of this study was to determine the within-and between-day reliability of spatio-temporal, plantar pressure, kinematic and kinetic measurements based on a novel, seven segment foot model applied in patients with Psoriatic Arthritis (PsA). Nine PsA patients and matched healthy adult controls underwent three-dimensional gait analysis on two occasions, one week apart using a seven segment foot model. A core-set of functional variables including inter-segment kinematics, kinetics, spatio-temporal and plantar pressure distribution were analysed using the coefficient of multiple correlation (CMC), Bland-Altman plots, intraclass correlation coefficients (ICC) and the standard error of measurement (SEM). Results showed excellent within- and between-day reliability for intersegment kinematic and kinetic data patterns with CMC values typically greater than 0.950 in a clinically stable cohort of PsA patients. Between-day reliability ranged from poor to excellent for absolute CMC values. Corrected CMC values were consistently higher across all variables ranging from fair-to-good to excellent. ICC values indicated excellent reliability for discrete spatio-temporal, plantar pressure, and ankle moment and power variables for both groups. Reliability for ground reaction forces and kinematic discrete variables ranged from fair-to-good to excellent. Standard error of measurement values ranged from 0.7° to 3.0° for discrete kinematic variables across both groups with greater variability in the PsA patients. In conclusion, intersegment kinematics and kinetics as well as spatio-temporal and plantar pressure can be reliably measured in PsA patients using a novel seven segment foot model. Some discrete kinematic variables have poor reliability and should not be used in prospective cohort and intervention studies.
本研究旨在确定基于新型七段式足模型在患有银屑病关节炎(PsA)患者中应用时,时空、足底压力、运动学和动力学测量的日内和日间可靠性。九名 PsA 患者和匹配的健康成人对照组在一周内两次进行三维步态分析,使用七段式足模型。使用多重相关系数(CMC)、Bland-Altman 图、组内相关系数(ICC)和测量标准误差(SEM)分析了包括节段间运动学、动力学、时空和足底压力分布在内的核心功能变量。结果表明,在临床稳定的 PsA 患者队列中,节段间运动学和动力学数据模式的日内和日间可靠性极好,CMC 值通常大于 0.950。绝对 CMC 值的日间可靠性范围从差到极好。校正后的 CMC 值在所有变量中均较高,范围从良好到极好。ICC 值表明离散时空、足底压力和踝关节力矩和功率变量在两组中均具有极好的可靠性。地面反作用力和运动学离散变量的可靠性范围从差到良好到极好。两组离散运动学变量的测量标准误差值范围为 0.7°至 3.0°,PsA 患者的变异性更大。总之,使用新型七段式足模型可以可靠地测量 PsA 患者的节段间运动学和动力学以及时空和足底压力。一些离散运动学变量的可靠性较差,不应在前瞻性队列和干预研究中使用。