Akaishi Leonardo, Vaz Rodrigo, Vilella Graziela, Garcez Rodrigo C, Tzelikis Patrick F
Brasilia Ophthalmologic Hospital (HOB), SQSW 306, Bloco A, Apartment 105, Brasilia DF 70640-000, Brazil.
J Ophthalmol. 2010;2010. doi: 10.1155/2010/717591. Epub 2010 Oct 5.
Purpose. To evaluate visual performance for near, intermediate, and distant vision; complaints of photic phenomena, and patient satisfaction with the new diffractive multifocal IOL used in eyes which underwent phacoemulsification. Methods. Two thousand and five hundred consecutive eyes undergoing Tecnis ZM900 multifocal IOL implantation were included in this retrospective analysis. The minimum followup of 3 months was required after the surgery. Patients were assessed for uncorrected near visual acuity (UNVA) at a fixed distance (33 cm), uncorrected intermediate visual acuity (UIVA) at 60 cm, and uncorrected distance visual acuity (UDVA). Using a subjective questionnaire, patients satisfaction, their independence from using glasses, and the perception of glare and halo phenomena were also evaluated at the last follow-up. Results. Two thousand and five hundred eyes of 1558 patients underwent cataract surgery and Tecnis ZM900 multifocal IOL implantation. Four hundred and eighty seven patients (31.3%) were men, and 1071 (68.7%) were women. The mean age of the patients was 66.17 years. A UDVA of 20/30 or better was achieved by 85% of eyes. A UNVA of J1 was achieved by 93.7% of eyes and that of J2 or better was achieved by 98%. A UIVA of J4 or better was achieved by 65% and J5 or better was achived by more than 82.8% of the eyes in the study. Glare and halos were reported as severe by only 6.1% and 2.12% of patients, respectively. Ninety seven percent reported complete spectacle independence and 88% stated that they are totally satisfied with their quality of vision and would choose to have the same lens implanted again after the first implant. Five percent of the eyes in the study needed a second procedure (enhancement) to achieve a better visual result. No patient underwent lens exchange. Conclusion. Excellent near, intermediate, and distant vision was observed in patients implanted with the Tecnis ZM900 diffractive multifocal IOL. Spectacle independence and a minimum occurrence of photic phenomena make this IOL an excellent option in patients with cataract.
目的。评估白内障超声乳化术后植入新型衍射多焦点人工晶状体(IOL)的患者在近、中、远距离的视觉表现、畏光现象主诉以及患者满意度。方法。本回顾性分析纳入了连续2500只接受Tecnis ZM900多焦点IOL植入的眼睛。术后需要至少3个月的随访。评估患者在固定距离(33厘米)的未矫正近视力(UNVA)、60厘米处的未矫正中视力(UIVA)以及未矫正远视力(UDVA)。在最后一次随访时,使用主观问卷评估患者满意度、是否不再依赖眼镜以及对眩光和光晕现象的感受。结果。1558例患者的2500只眼睛接受了白内障手术并植入了Tecnis ZM900多焦点IOL。487例患者(31.3%)为男性,1071例(68.7%)为女性。患者的平均年龄为66.17岁。85%的眼睛达到了20/30或更好的UDVA。93.7%的眼睛达到了J1的UNVA,98%的眼睛达到了J2或更好的UNVA。在研究中,65%的眼睛达到了J4或更好的UIVA,超过82.8%的眼睛达到了J5或更好的UIVA。分别只有6.1%和2.12%的患者报告眩光和光晕严重。97%的患者报告完全不再依赖眼镜,88%的患者表示他们对视力质量完全满意,并会选择在首次植入后再次植入相同的晶状体。研究中5%的眼睛需要进行二次手术(强化)以获得更好的视觉效果。没有患者进行晶状体置换。结论。植入Tecnis ZM900衍射多焦点IOL的患者在近、中、远距离均观察到了出色的视力。不再依赖眼镜以及畏光现象发生率低使得这种IOL成为白内障患者的一个极佳选择。