Confirmation of high blood flow rates through 150 mu filter/high-flow tubing.

作者信息

Iserson K V, Knauf M A

机构信息

Department of Surgery, University of Arizona College of Medicine, Tucson 85724.

出版信息

J Emerg Med. 1990 Nov-Dec;8(6):689-91. doi: 10.1016/0736-4679(90)90278-4.

DOI:10.1016/0736-4679(90)90278-4
PMID:2096162
Abstract

Many new products designed to assist in rapid blood infusion are appearing. Some highly touted and routinely used devices for intravenous (IV) infusion have recently been shown to be, at least in part, defective. A tubing with an in-line 150 mu filter (150 mu High-Flow Blood Filter; Saftifilter Blood Administration Sets; Cutter Biological, Berkeley, CA 94710) has recently been introduced to facilitate rapid blood transfusion. It is claimed that at least 8.5 units of blood can be rapidly run through each set before replacement is necessary. To test this under simulated clinical conditions, four sets of ten random units of outdated erythrocytes at 4 to 9 degrees C were each admixed with 250 mL 70 degrees C 0.9 NaCl and infused through the system under a constant 300 mmHg pressure. Two sets infused through unmodified tubing flowed at an average of 25 mL/sec (1500 mL/min) before there was an appreciable slowing of the flow rate. Two sets with 8 Fr catheters attached infused at an average of 22 mL/sec (1320 mL/min) before there was an appreciable slowing of the flow rate. Even after the flow slowed, the 9th and 10th units infused at an average greater than 10 mL/sec (600 mL/min). The tubing/filter exceeded the manufacturer's published claims. This tubing/filter appears to be one element that could be an effective component of a high-flow infusion system.

摘要

相似文献

1
Confirmation of high blood flow rates through 150 mu filter/high-flow tubing.
J Emerg Med. 1990 Nov-Dec;8(6):689-91. doi: 10.1016/0736-4679(90)90278-4.
2
Flow characteristics of admixed erythrocytes through medex tubing with a pall filter.混合红细胞通过带有颇尔过滤器的美敦力管路的流动特性。
J Emerg Med. 1988 Jul-Aug;6(4):269-71. doi: 10.1016/0736-4679(88)90360-5.
3
Efficacy of large-bore intravenous fluid administration sets designed for rapid volume resuscitation.专为快速容量复苏设计的大口径静脉输液装置的疗效。
Crit Care Med. 1990 May;18(5):540-3. doi: 10.1097/00003246-199005000-00016.
4
Factors affecting rapid fluid resuscitation with large-bore introducer catheters.影响使用大口径穿刺导管进行快速液体复苏的因素。
J Trauma. 1989 Jun;29(6):856-60. doi: 10.1097/00005373-198906000-00025.
5
Factors affecting flow through blood administration sets.影响血液输注装置血流的因素。
Eur J Anaesthesiol. 1997 May;14(3):333-9. doi: 10.1046/j.1365-2346.1997.00151.x.
6
An evaluation of the Rapid Infusion System.快速输液系统的评估
Anaesthesia. 1992 Jul;47(7):597-600. doi: 10.1111/j.1365-2044.1992.tb02333.x.
7
Performance assessment of intravenous catheters for massive transfusion: A pragmatic in vitro study.静脉导管在大量输血中的性能评估:一项实用的体外研究。
Transfusion. 2021 Jun;61(6):1721-1728. doi: 10.1111/trf.16399. Epub 2021 Apr 13.
8
Rapid volume replacement for hypovolemic shock: a comparison of techniques and equipment.低血容量性休克的快速容量补充:技术与设备的比较
J Trauma. 1984 May;24(5):428-31. doi: 10.1097/00005373-198405000-00010.
9
Administration of microaggregate filtered blood using a manual infusion pump.
Transfusion. 1980 Mar-Apr;20(2):145-52. doi: 10.1046/j.1537-2995.1980.20280169954.x.
10
[Technical constraints in rapid vascular fluid replacement].[快速血管内液体补充的技术限制]
Ann Fr Anesth Reanim. 1990;9(5):433-42. doi: 10.1016/s0750-7658(05)80950-5.