Zilling T, Walther B S, Holmin T
Department of Surgery, Lund University, Sweden.
In Vivo. 1990 Jul-Aug;4(4):273-5.
Segmental liver resection was performed in 14 pigs. The pigs were randomized either to resection with conventional finger fracture technique or resection with linear stapling device (TA-90R, US Surgical Corporation). The median time for resection was shorter in the stapled group, although the difference was not statistically significant. The median weight of the specimen was the same in both groups. The median postoperative Haemoglobin value was somewhat lower in the finger fracture resected group as compared to the stapler resected group, 82.5 g/l versus 87.5 g/l, but there was no statistically significant difference between the groups. Blood loss, estimated by counting the number of compresses, amounted to 188 ml for the finger fracture resected group and 181 ml for the stapler resected group. At the post-mortem examination there were no signs of bile leakage or postoperative blood loss in any of the operated animals. This study demonstrates that hepatic resection in the pig can be performed quickly and safely by using linear stapling device. Stapler resection was easier and somewhat quicker to perform than conventional hepatic resection.
对14头猪实施了肝段切除术。这些猪被随机分为两组,一组采用传统手指骨折技术进行切除,另一组采用线性缝合器械(TA - 90R,美国外科公司)进行切除。吻合器组的中位切除时间较短,尽管差异无统计学意义。两组标本的中位重量相同。手指骨折切除组术后血红蛋白的中位值略低于吻合器切除组,分别为82.5 g/l和87.5 g/l,但两组之间无统计学显著差异。通过计算敷料数量估计,手指骨折切除组的失血量为188 ml,吻合器切除组为181 ml。在尸检时,任何一只手术动物均未出现胆汁漏或术后出血的迹象。本研究表明,使用线性缝合器械可在猪身上快速、安全地进行肝切除术。与传统肝切除术相比,吻合器切除术操作更容易,且稍快一些。