Suppr超能文献

Development of an x-ray imaging system for the Laser Megajoule (LMJ).

作者信息

Turk G, Reverdin C, Gontier D, Darbon S, Dujardin C, Ledoux G, Hamel M, Simic V, Normand S

机构信息

CEA, DAM, DIF, F-91297 Arpajon, France.

出版信息

Rev Sci Instrum. 2010 Oct;81(10):10E509. doi: 10.1063/1.3475788.

Abstract

This imaging system aims at recording images of the core size and shape of an imploding deuterium-tritium (DT) microballoon on LMJ inertial confinement fusion (ICF) experiments. Image acquisition is difficult due to the harsh surrounding created by the fusion reaction, which affects system specifications. This one is made of a scintillator, an optical relay, and a CCD camera shielded from the surrounding. The system was tested on different facilities at CEA/DIF, where a spatial resolution of 120 μm was achieved and gamma dose up to 20 rad effects were measured. Setup and performed test are described.