Many efforts are being made to develop new alternative in vitro test methods for the eye irritation test. Here we report a new reconstructed human corneal epithelial model (MCTT HCE model) prepared from primary-cultured human limbal epithelial cells as a new alternative in vitro eye irritation test method. In histological and immunohistochemical observation, MCTT HCE model displayed a morphology and biomarker expressions similar to intact human cornea. Moreover, the barrier function was well preserved as measured by high transepithelial electrical resistance, effective time-50 for Triton X-100, and corneal thickness. To employ the model as a new alternative method for eye irritation test, protocol refinement was performed and optimum assay condition was determined including treatment time, treatment volume, post-incubation time and rinsing method. Using the refined protocol, 25 reference chemicals with known eye irritation potentials were tested. With the viability cut-off value at 50%, chemicals were classified to irritant or non-irritant. When compared with GHS classification, the MCTT HCE model showed the accuracy of 88%, sensitivity of 100% and specificity of 77%. These results suggest that the MCTT HCE model might be useful as a new alternative eye irritation test method.
目前正在努力开发新的替代眼部刺激性测试的体外检测方法。在这里,我们报告了一种新型的人角膜上皮细胞重建模型(MCTT HCE 模型),该模型由原代培养的人角膜缘上皮细胞制备,作为一种新的替代体外眼刺激性测试方法。在组织学和免疫组织化学观察中,MCTT HCE 模型显示出与完整人角膜相似的形态和生物标志物表达。此外,高跨上皮电阻、Triton X-100 的有效 50 时间和角膜厚度的测量表明,屏障功能得到了很好的保留。为了将该模型用作新的替代眼刺激性测试方法,我们进行了方案优化,并确定了最佳的检测条件,包括处理时间、处理体积、孵育后时间和冲洗方法。使用优化后的方案,对 25 种具有已知眼部刺激性潜力的参考化学品进行了测试。以 50%的存活率为截断值,将化学品分为刺激性或非刺激性。与 GHS 分类相比,MCTT HCE 模型的准确率为 88%,灵敏度为 100%,特异性为 77%。这些结果表明,MCTT HCE 模型可能是一种有用的新型替代眼部刺激性测试方法。