van der Heiden C, Desplanque J, Bakker H D
Clin Chim Acta. 1977 Nov 1;80(3):519-27. doi: 10.1016/0009-8981(77)90146-2.
Some kinetic properties of liver OCT from a patient with OCT deficiency were studied. Contrary to controls, in which two pH optima were observed (pH 7.7 and pH 8.5), only the pH optimum of 8.5 could be demonstrated in our patient. From KM studies at pH 7.7 and pH 8.5, the most striking abnormalities in comparison with human controls were (a) a strongly increased KM (ornithine) at pH 7.7, but less pronounced at pH 8.5, (b) a higher VMAX at pH 8.5 compared with the VMAX at pH 7.7 and (c) the absence of substate inhibition at pH 8.5 to ornithine was elevated up to a concentration above approximately 1.5 mM.
对一名患有鸟氨酸氨基甲酰转移酶(OCT)缺乏症患者的肝脏OCT的一些动力学特性进行了研究。与观察到两个pH最佳值(pH 7.7和pH 8.5)的对照组相反,在我们的患者中仅能证明pH 8.5的最佳值。通过在pH 7.7和pH 8.5下进行米氏常数(KM)研究,与人类对照组相比,最显著的异常情况为:(a)在pH 7.7时KM(鸟氨酸)大幅增加,但在pH 8.5时不那么明显;(b)与pH 7.7时的最大反应速度(VMAX)相比,pH 8.5时的VMAX更高;(c)在pH 8.5时不存在底物抑制,直至鸟氨酸浓度升高至约1.5 mM以上。