Suppr超能文献

软衬材料与纤维增强型义齿基托树脂的黏结强度。

Bond strength of soft liners to fiber-reinforced denture-base resin.

机构信息

Department of Biomaterials Science, Institute of Dentistry, University of Turku, Turku, Finland.

出版信息

J Prosthodont. 2010 Dec;19(8):620-4. doi: 10.1111/j.1532-849X.2010.00642.x. Epub 2010 Nov 5.

Abstract

PURPOSE

This study evaluated bond strengths of four soft liners to fiber-reinforced (FR) and unreinforced poly methyl(methacrylate) (PMMA) denture-base resin.

MATERIALS AND METHODS

The autopolymerized denture-base resin Palapress Vario (Heraus Kulzer GmbH, Hanau, Germany) was used as the substrate (15 × 15 × 5 mm³). The test group consisted of substrates reinforced with porous PMMA preimpregnated unidirectional glass fibers (Stick [StickTech, Turku, Finland]) (PMMA + FR group), and the control group was unreinforced acrylic resin (PMMA group) (n = 80 per group). One of four soft liners (Ufi Gel SC [Voco, Cuxhaven, Germany], Sofreliner Tough [Tokuyama Dental Corporation, Tokyo, Japan], Vertex SoftSil 25 [Vertex-Dental B.V., Zeist, The Netherlands], and Eversoft [Dentsply Austenal, York, PA]) was placed and cured between two substrates using a polyethylene ring (10 mm inner radius, 3 mm height). Tensile bond strength tests (crosshead speed = 10 mm/min) were performed, and the results were analyzed using analysis of variance followed by Tukey's test (p= 0.05). Fracture surfaces were categorized as adhesive or cohesive-mixed modes, and failure types were statistically analyzed using chi-square test.

RESULTS

FR did not affect the bond strength results significantly (p > 0.05) except for Ufi Gel SC. Significant differences in bond strength were found among the reline materials (p < 0.001). FR specimens showed a significantly higher number of cohesive-mixed fractures compared to unreinforced specimens (p < 0.05), except for plasticized acrylic-based reline material (Eversoft [Dentsply Austenal]), which showed fewer cohesive-mixed failures with FR.

CONCLUSIONS

The choice of appropriate reline material system with FR acrylic resin is important for the soft liner/denture-base polymer bond. Glass FR did not have a decreasing effect on the bond strength, except for Ufi Gel SC.

摘要

目的

本研究评估了四种软衬材料与纤维增强(FR)和未增强聚甲基(甲基丙烯酸酯)(PMMA)义齿基托树脂的粘结强度。

材料与方法

使用自聚合义齿基托树脂 Palapress Vario(德国贺利氏古莎有限公司,哈瑙)作为基底(15×15×5mm³)。实验组由多孔 PMMA 预浸渍单向玻璃纤维增强的基底组成(Stick[StickTech,图尔库,芬兰])(PMMA+FR 组),对照组为未增强的丙烯酸树脂(PMMA 组)(每组 80 个)。将四种软衬材料之一(Ufi Gel SC[Voco,库克斯港,德国]、Sofreliner Tough[日本德山齿科株式会社]、Vertex SoftSil 25[荷兰 Vertex-Dental B.V.]和 Eversoft[美国登士柏安格公司,约克,宾夕法尼亚州])放置在两个基底之间并用聚乙烯环(内半径 10mm,高 3mm)固化。进行拉伸粘结强度测试(十字头速度=10mm/min),并使用方差分析和 Tukey 检验(p=0.05)进行结果分析。对断裂表面进行分类为粘结或粘结-混合模式,并使用卡方检验对失效类型进行统计学分析。

结果

除 Ufi Gel SC 外,FR 对粘结强度结果没有显著影响(p>0.05)。不同的衬垫材料之间的粘结强度有显著差异(p<0.001)。与未增强的标本相比,FR 标本显示出更高数量的粘结-混合断裂(p<0.05),除了塑料化丙烯酸基衬垫材料(Eversoft[美国登士柏安格公司])外,其与 FR 一起显示出较少的粘结-混合失效。

结论

对于软衬/义齿基托聚合物的粘结,选择合适的 FR 丙烯酸树脂衬垫材料系统很重要。玻璃 FR 对粘结强度没有降低作用,除了 Ufi Gel SC。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验