Suppr超能文献

[血液相容性中纤维蛋白原吸附及其转化反应的研究]

[Research on fibrinogen adsorption and its transformation response in hemocompatibility].

作者信息

Jin Jian, Wan Guojiang, Zhao Ansha, Lei Yuechang, Yang Ying, Huang Nan, Wu Xi, Yang Ping, Leng Yongxiang, Chen Junying, Hou Mingyong

机构信息

Chengdu Railway Central Hospital, Chengdu 610081, China.

出版信息

Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2010 Oct;27(5):1062-5.

Abstract

In this research,enzyme linked immunoassay (ELISA) was used to assay the fibrinogen (FIG) adsorbed on the Ti-O films and on the low temperature isotropic carbon (LTIC) films which were planted in the femoral arteries of 6 mongrel dogs for six months, respectively. The Ti-O films were planted in the dogs' left femoral arteries; the LTIC films as controls were planted in the dogs' right femoral arteries. The contents adsorbed in these two kinds of films were examined by scanning electron microscopy (SEM). The quantities of FIG adhered or denatured on the Ti-O films or LTIC films determined by ELISA, and the platelets adhered on the two kinds of films examined by SEM were of significant difference between the two groups. In the blood vessel, the amount of FIG adhered on biomaterial was related to its component and construction. FIG released electron to the biomaterial and induced the unfolding of C term of the gamma-chain of FIG, and the conjugation point and effect point were exposed. In conclusion, the biomaterial, which has the capability for resisting the electron release from FIG as well as for maintaining the invariable electric condition, will have excellent hemocompatibility.

摘要

在本研究中,采用酶联免疫吸附测定法(ELISA)检测分别植入6只杂种犬股动脉6个月的TiO薄膜和低温各向同性碳(LTIC)薄膜上吸附的纤维蛋白原(FIG)。TiO薄膜植入犬的左股动脉;作为对照的LTIC薄膜植入犬的右股动脉。通过扫描电子显微镜(SEM)检查这两种薄膜中吸附的物质。通过ELISA测定TiO薄膜或LTIC薄膜上粘附或变性的FIG量,通过SEM检查两种薄膜上粘附的血小板,两组之间存在显著差异。在血管中,生物材料上粘附的FIG量与其成分和结构有关。FIG向生物材料释放电子,诱导FIGγ链C端展开,使结合点和效应点暴露。总之,具有抵抗FIG释放电子并维持恒定电状态能力的生物材料将具有优异的血液相容性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验