Small Animal Clinic Internal Medicine, University of Giessen, Germany.
J Vet Intern Med. 2011 Jan-Feb;25(1):65-70. doi: 10.1111/j.1939-1676.2010.0637.x. Epub 2010 Nov 23.
Surgical and interventional therapy for occlusion of a patent ductus arteriosus (PDA) in small dogs is challenging. Interventional closure of a PDA is rarely described in small dogs.
Transvenous single-coil occlusion of a PDA in small (≤3.0 kg) dogs is possible and safe.
Twenty-one client-owned dogs with a left-to-right shunting PDA.
Prospective clinical study. Inclusion criteria were a left-to-right shunting PDA and a body weight ≤3.0 kg. Dogs with additional congenital cardiac diseases were excluded. Without arterial access, a single detachable coil was implanted by a transvenous approach with a 4 Fr catheter.
Twenty-one dogs were the study population with Chihuahua and Yorkshire Terrier being the commonest breeds (n = 6 and n = 5, respectively). There were 14 female and 7 male dogs. The age range was 1.9-83.5 months (median, 7.7 months), and the body weight was 1.0-2.9 kg (1.87 ± 0.45). By angiography, the minimal ductal diameter measured 1.2-2.4 mm (median, 1.8 mm) and the PDA ampulla diameter was 2.4-5.9 mm (median, 4.6 mm). Coil implantation was successful in all dogs. After detachment of the coil from the delivery cable, repositioning of the pulmonary loop of the coil became necessary in 1 dog. The prevalence of immediate closure was 76%. The prevalence of cumulative closure was 90%.
For an experienced cardiologist, transvenous occlusion of a PDA in small dogs is possible with a 4 Fr catheter and a commercial single detachable coil. Arterial access is not essential. The procedure is safe and successful in experienced hands.
小型犬动脉导管未闭(PDA)的手术和介入治疗具有挑战性。小型犬的 PDA 介入封堵很少见。
在小型(≤3.0kg)犬中,经静脉单圈 PDA 封堵是可行且安全的。
21 只伴有左向右分流的 PDA 的患犬。
前瞻性临床研究。纳入标准为存在左向右分流的 PDA 和体重≤3.0kg。存在其他先天性心脏病的犬被排除在外。未进行动脉入路,通过经静脉途径使用 4Fr 导管植入单个可解脱的线圈。
21 只犬为研究对象,其中吉娃娃和约克夏梗犬最为常见(分别为 6 只和 5 只)。14 只为雌性,7 只为雄性。年龄范围为 1.9-83.5 个月(中位数,7.7 个月),体重为 1.0-2.9kg(1.87±0.45)。通过血管造影,最小的导管直径为 1.2-2.4mm(中位数,1.8mm),PDA 壶腹直径为 2.4-5.9mm(中位数,4.6mm)。所有犬的线圈植入均成功。在从输送电缆上分离线圈后,1 只犬的线圈肺动脉环需要重新定位。即刻闭合率为 76%。累计闭合率为 90%。
对于经验丰富的心脏病专家来说,使用 4Fr 导管和商业性的单个可解脱线圈经静脉封堵小型犬的 PDA 是可行的。动脉入路并非必需。在经验丰富的手中,该操作安全且成功。