Large volume injection-programmable temperature vaporization-gas chromatography-mass spectrometry (LVI-PTV-GC-MS) was optimized for the determination of estrone (E1), 17β-estradiol (E2), 17α-ethynyl estradiol (EE2), mestranol (MeEE2) and estriol (E3) for their determination in environmental samples (estuarine water, wastewater, fish bile and fish homogenate) after derivatization with 25 μL (BSTFA+1% TMCS) and 125 μL of pyridine. Experimental designs such as Plackett-Burman (PBD) and central composite designs (CCDs) were used to optimize the LVI-PTV variables (cryo-focusing temperature, vent time, vent flow, vent pressure, injection volume, purge flow to split vent, splitless time and injection speed). Optimized conditions were as follows: 45 μL of n-hexane extract are injected at 60°C and 6 μL/s with a vent flow and a vent pressure of 50 mL/min and 7.7 psi, respectively, during 5 min; then the split valve is closed for 1.5 min and afterwards the injector is cleaned at 100 mL/min before the next injection. The method was applied to the determination of estrogenic compounds in environmental samples such as estuarine water, wastewater, and fish homogenate and bile. Limits of detection (0.04-0.15 ng/L for water samples, 0.04-0.67 ng/g for fish bile and 0.1-7.5 ng for fish homogenate) obtained were approx. ten times lower than those obtained by means of a common split/splitless inlet.
大体积进样-程序升温吹扫捕集-气相色谱-质谱法(LVI-PTV-GC-MS)经过衍生化(BSTFA+1%TMCS 和 125 μL 吡啶)后,用于测定环境样品(河口水样、废水、鱼肝胆汁和鱼匀浆)中的雌酮(E1)、17β-雌二醇(E2)、17α-乙炔基雌二醇(EE2)、美雌醇(MeEE2)和雌三醇(E3)。实验设计如 Plackett-Burman(PBD)和中心复合设计(CCD)用于优化 LVI-PTV 变量(冷聚焦温度、吹扫时间、吹扫流量、吹扫压力、进样体积、吹扫分流流量、不分流时间和进样速度)。优化条件如下:45 μL 正己烷提取物在 60°C 和 6 μL/s 下进样,分别在 5 分钟内用 50 mL/min 和 7.7 psi 的吹扫流量和吹扫压力进行吹扫;然后关闭分流阀 1.5 分钟,之后在进行下一次进样前以 100 mL/min 的速度清洗进样器。该方法应用于测定河口水样、废水和鱼肝胆汁等环境样品中的雌激素化合物。检测限(水样为 0.04-0.15 ng/L,鱼肝胆汁为 0.04-0.67 ng/g,鱼匀浆为 0.1-7.5 ng)约为普通分流/不分流进样的十倍。