Suppr超能文献

真菌色素会抑制基质辅助激光解吸/电离飞行时间质谱分析深色真菌。

Fungal pigments inhibit the matrix-assisted laser desorption/ionization time-of-flight mass spectrometry analysis of darkly pigmented fungi.

机构信息

National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA.

出版信息

Anal Biochem. 2011 Apr 1;411(1):122-8. doi: 10.1016/j.ab.2010.11.025. Epub 2010 Nov 19.

Abstract

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been used to discriminate moniliaceous fungal species; however, darkly pigmented fungi yield poor fingerprint mass spectra that contain few peaks of low relative abundance. In this study, the effect of dark fungal pigments on the observed MALDI mass spectra was investigated. Peptide and protein samples containing varying concentrations of synthetic melanin or fungal pigments extracted from Aspergillus niger were analyzed by MALDI-TOF and MALDI-qTOF (quadrupole TOF) MS. Signal suppression was observed in samples containing greater than 250ng/μl pigment. Microscopic examination of the MALDI sample deposit was usually heterogeneous, with regions of high pigment concentration appearing as black. Acquisition of MALDI mass spectra from these darkly pigmented regions of the sample deposit yielded poor or no M+H ion signal. In contrast, nonpigmented regions within the sample deposit and hyphal negative control extracts of A. niger were not inhibited. This study demonstrated that dark fungal pigments inhibited the desorption/ionization process during MALDI-MS; however, these fungi may be successfully analyzed by MALDI-TOF MS when culture methods that suppress pigment expression are used. The addition of tricyclazole to the fungal growth media blocks fungal melanin synthesis and results in less melanized fungi that may be analyzed by MALDI-TOF MS.

摘要

基质辅助激光解吸电离飞行时间质谱(MALDI-TOF MS)已被用于鉴别假丝酵母真菌;然而,深色素真菌产生的指纹质谱峰少且相对丰度低。在这项研究中,研究了深色真菌色素对观察到的 MALDI 质谱的影响。含有不同浓度合成黑色素或从黑曲霉中提取的真菌色素的肽和蛋白质样品通过 MALDI-TOF 和 MALDI-qTOF(四极杆飞行时间)MS 进行分析。在含有大于 250ng/μl 色素的样品中观察到信号抑制。MALDI 样品沉积物的显微镜检查通常是不均匀的,高色素浓度区域呈现黑色。从样品沉积物的这些深色素区域获取 MALDI 质谱会产生较差或没有 M+H 离子信号。相比之下,样品沉积物中的非色素区域和黑曲霉的菌丝阴性对照提取物不受抑制。这项研究表明,深色真菌色素抑制了 MALDI-MS 中的解吸/电离过程;然而,当使用抑制色素表达的培养方法时,这些真菌可以通过 MALDI-TOF MS 成功分析。在真菌生长培养基中添加三唑酮可阻断真菌黑色素的合成,从而产生较少黑色素的真菌,可通过 MALDI-TOF MS 进行分析。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验