A new method based on solid phase dispersion-pressurized liquid extraction (PLE) followed by gas chromatography-mass spectrometry (GC-MS) has been developed for the determination of 26 suspected fragrance allergens (all the regulated in the EU Cosmetics Directive amenable by GC, as well as pinene and methyleugenol) in cosmetic samples. The effects of the temperature, extraction time and solvent, and dispersing sorbent, affecting the whole proposed procedure, have been evaluated using a multifactor strategy. The optima conditions after the analysis of main and second order effects entailed the extraction at 120°C for 15 min, using hexane/acetone as solvent, and florisil as dispersing sorbent. The method performance has been studied, showing good linearity (R≥0.996) as well as good precision (RSD≤10%). Detection limits (S/N=3) ranged from 0.000001 to 0.0002% (w/w), values far below the established restrictions as regard labelling in the European Cosmetics Regulation. Reliability was demonstrated through the quantitative recoveries of all the studied compounds. The absence of matrix effects allowed quantification of the compounds by calibration with standard solutions. The analysis of 10 samples (several moisturizing and anti-wrinkle creams and lotions, hand creams, and sunscreen and after-sun creams), covering very different matrices, showed the presence of suspected allergens in all the analyzed samples; in fact, half of the samples contained an elevated number of them. Although the ubiquity of these compounds was demonstrated, labelling was in all cases in consonance with the European Cosmetics Regulation.
一种基于固相分散-加压液相萃取(PLE)结合气相色谱-质谱(GC-MS)的新方法已经被开发出来,用于测定化妆品样品中的 26 种疑似香料过敏原(所有受欧盟化妆品指令监管的、可通过 GC 测定的物质,以及蒎烯和甲基丁香酚)。采用多因素策略评估了温度、提取时间和溶剂、以及分散吸附剂对整个提议程序的影响。在分析主效应和二阶效应后,最佳条件为在 120°C 下提取 15 分钟,使用正己烷/丙酮作为溶剂,并用弗罗里硅土作为分散吸附剂。研究了该方法的性能,结果表明其具有良好的线性(R≥0.996)和良好的精密度(RSD≤10%)。检测限(S/N=3)范围为 0.000001%至 0.0002%(w/w),远低于欧洲化妆品法规中关于标签的规定限制。通过对所有研究化合物的定量回收证明了该方法的可靠性。基质效应的不存在允许通过用标准溶液进行校准来定量化合物。对 10 个样品(包括几种保湿和抗皱霜和乳液、护手霜以及防晒和晒后霜)进行分析,涵盖了非常不同的基质,结果表明所有分析样品中都存在疑似过敏原;事实上,一半的样品中含有大量的过敏原。尽管证明了这些化合物的普遍存在,但在所有情况下,标签都符合欧洲化妆品法规。