Arcentales Andrés, Giraldo Beatriz F, Caminal Pere, Diaz Iván, Benito Salvador
Dept. ESAII, Universitat Politècnica de Catalunya (UPC), Spain.
Annu Int Conf IEEE Eng Med Biol Soc. 2010;2010:2485-8. doi: 10.1109/IEMBS.2010.5626533.
A considerable number of patients in weaning process have problems to keep spontaneous breathing during the trial and after it. This study proposes to extract characteristic parameters of the RR series and respiratory flow signal according to the patients' condition in weaning test. Three groups of patients have been considered: 93 patients with successful trials (group S), 40 patients that failed to maintain spontaneous breathing (group F), and 21 patients who had successful weaning trials, but that had to be reintubated before 48 hours (group R). The characterization was performed using spectral analysis of the signals, through the power spectral density, cross power spectral density and Coherence method. The parameters were extracted on the three frequency bands (VLF, LF and HF), and the principal statistical differences between groups were obtained in bands of VLF and HF. The results show an accuracy of 76.9% in the classification of the groups S and F.