一台2.35 T的三线圈射频探头:在小动物(23)Na和超极化(129)Xe磁共振成像中的潜在应用。

A three-coil RF probe-head at 2.35 T: Potential applications to the (23)Na and to the hyperpolarized (129)Xe MRI in small animals.

作者信息

Asfour Aktham

机构信息

INSERM, U836, GIN, Team 5, Grenoble, F-38000, France.

出版信息

Annu Int Conf IEEE Eng Med Biol Soc. 2010;2010:5693-9. doi: 10.1109/IEMBS.2010.5627882.

Abstract

We present in this paper a dedicated home-built RF probe-head for the MRI of rat brain at 2.35 T. This probe consists of an association of three coils: a double-tuned birdcage coil, which could be used for both transmitting and receiving, and a single-tuned surface coil that is used for the only receiving. This single-tuned coil is actively decoupled from the double-tuned volume coil. The active decoupling is based on the pole insertion technique using PIN diodes circuitry. This development was initially motivated by its potential and future application to the brain perfusion measurements by the MRI of hyperpolarized xenon-129 (HP (129)Xe). However, one of underlying ideas behind this work is to proceed well beyond this specific application. Particularly, the developed coil could also be dedicated for the sodium-23 ((23)Na) MRI in the rat brain. Indeed we tried to make the design versatile, simple and easy to replicate by other research groups, with a low cost, minimum development time and accepted performances. We believe that this design could by useful for groups who consider building own hardware. This is why we describe in some details the practical aspects of the workbench design as well as the coil characterization. For simplicity reasons, the first results of developed prototype were obtained at 100 MHz and 26.4 MHz (proton and sodium-23 frequencies at 2.35 T). MR images of phantoms were realized. In-vivo (1)H images and (23)Na spectra of the rat brain were also obtained. Future validation would concern the MRI of HP (129)Xe.

摘要

在本文中,我们展示了一种专门为2.35T大鼠脑磁共振成像(MRI)自制的射频探头。该探头由三个线圈组成:一个可用于发射和接收的双调谐鸟笼线圈,以及一个仅用于接收的单调谐表面线圈。这个单调谐线圈与双调谐体线圈实现了有源去耦。有源去耦基于使用PIN二极管电路的极插入技术。这项研发最初的动机是其在超极化氙-129(HP (129)Xe)MRI脑灌注测量中的潜力和未来应用。然而,这项工作背后的一个潜在想法是超越这一特定应用。特别是,所开发的线圈也可用于大鼠脑的钠-23((23)Na)MRI。事实上,我们试图使设计具有通用性、简单易复制,让其他研究团队能够以低成本、最短的开发时间和可接受的性能进行复制。我们相信这种设计对那些考虑自行构建硬件的团队会有用。这就是为什么我们详细描述了工作台设计的实际方面以及线圈特性。出于简化的原因,所开发原型的首批结果是在100MHz和26.4MHz(2.35T时的质子和钠-23频率)下获得的。实现了体模的磁共振图像。还获得了大鼠脑的体内(1)H图像和(23)Na谱。未来的验证将涉及HP (129)Xe的MRI。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验