Suppr超能文献

原发和改良 House Brackmann 面神经分级系统之间具有良好的相关性。

Good correlation between original and modified House Brackmann facial grading systems.

机构信息

Facial Nerve Center, Mass Eye and Ear Infirmary, Boston, Massachusetts, USA.

出版信息

Laryngoscope. 2011 Jan;121(1):47-50. doi: 10.1002/lary.21163.

Abstract

OBJECTIVES/HYPOTHESIS: Subjective scales of facial function were plagued with reporting variations until the House-Brackmann scale was described in 1985. Despite its utility, weaknesses were identified, including noninclusion of synkinesis phenomena and insensitivity to segmental weakness. Therefore, the scale was recently revised to address these weaknesses. The objective of this investigation was to determine agreement between the original and the updated House-Brackmann scales.

STUDY DESIGN

Prospective clinical trial.

METHODS

Fifty consecutive new facial paralysis patients underwent standardized facial videography while performing facial movements. Video clips were scored by three independent facial nerve clinicians. The time it took to produce a score for each method was tracked. Interobserver correlations were calculated, and comparisons were made between scores by using the original and modified House-Brackmann scales.

RESULTS

: Interobserver correlation was high for both House-Brackmann scales. Overall scores were in excellent agreement (difference of 0.1 ± 0.5, no statistical difference), although the modified scale took substantially longer to calculate (120 seconds ± 20 seconds vs. 30 seconds ± 10 seconds, P < .001).

CONCLUSIONS

We found substantial grading correlation between the original and the newly modified House-Brackmann scales. Because of specific zonal and synkinesis scoring, the modified scale took longer to score.

摘要

目的/假说:主观面部功能量表一直存在报告差异,直到 1985 年 House-Brackmann 量表问世。尽管该量表具有实用性,但也存在一些弱点,包括未包括联带运动现象和对节段性无力不敏感。因此,该量表最近进行了修订,以解决这些弱点。本研究的目的是确定原始和更新的 House-Brackmann 量表之间的一致性。

研究设计

前瞻性临床试验。

方法

50 例连续新发面瘫患者在进行面部运动时接受标准化面部录像。三位独立的面神经临床医生对视频片段进行评分。记录每种方法产生评分所需的时间。计算了观察者间相关性,并使用原始和改良 House-Brackmann 量表对评分进行了比较。

结果

两种 House-Brackmann 量表的观察者间相关性均较高。总体评分具有极好的一致性(差异为 0.1 ± 0.5,无统计学差异),尽管改良量表的计算时间明显更长(120 秒±20 秒与 30 秒±10 秒,P<.001)。

结论

我们发现原始和新修订的 House-Brackmann 量表之间存在显著的分级相关性。由于特定的区域和联带运动评分,改良量表的评分时间更长。