Morris Barry F, Vandewalle Kraig S, Hensley Donna M, Bartoloni Joseph A
Dunn Dental Clinic, Wilford Hall Medical Center, 1615 Truemper St., Lackland AFB, TX 78236, USA.
Mil Med. 2010 Nov;175(11):901-6. doi: 10.7205/milmed-d-10-00032.
The authors conducted a study to determine the validity of two commercially available in-office dental unit waterline test kits compared to the gold standard, R2A agar. Samples were collected from the air/water syringes of dental units and cultured on HPC Samplers, Petrifilm AC Plates, and R2A agar plates. HPC Samplers and R2A agar plates were incubated for 7 days and counted manually using magnification. Petrifilm AC Plates were counted after incubation time of 5 and 7 days using an electronic-plate reader. Validity measurements were calculated using a cutoff value < or = 500 colony-forming units per milliliter. The accuracy for the HPC Sampler compared to R2A agar was 71%. The accuracy for the Petrifilm AC Plates at 5 and 7 days was 79% and 87% compared to R2A agar. The Petrifilm AC Plate (7-day incubation) demonstrated higher sensitivity, specificity, predictive values, and accuracy than the HPC Sampler kit.
作者开展了一项研究,以确定与金标准R2A琼脂相比,两种市售的牙科综合治疗台水线检测试剂盒的有效性。从牙科综合治疗台的空气/水注射器中采集样本,并在HPC采样器、Petrifilm AC平板和R2A琼脂平板上培养。HPC采样器和R2A琼脂平板培养7天,使用放大镜进行手动计数。Petrifilm AC平板在培养5天和7天后,使用电子平板读数器进行计数。使用每毫升<或=500菌落形成单位的临界值计算有效性测量值。与R2A琼脂相比,HPC采样器的准确率为71%。与R2A琼脂相比,Petrifilm AC平板在5天和7天的准确率分别为79%和87%。Petrifilm AC平板(培养7天)显示出比HPC采样器试剂盒更高的敏感性、特异性、预测值和准确率。