Suppr超能文献

基于模型的动态胰岛素敏感性和分泌测试(DISST)的设计与临床预试验

Design and clinical pilot testing of the model-based dynamic insulin sensitivity and secretion test (DISST).

作者信息

Lotz Thomas F, Chase J Geoffrey, McAuley Kirsten A, Shaw Geoffrey M, Docherty Paul D, Berkeley Juliet E, Williams Sheila M, Hann Christopher E, Mann Jim I

机构信息

Centre for Bioengineering, University of Canterbury, and Department of Intensive Medicine, Christchurch Hospital, Christchurch, New Zealand.

出版信息

J Diabetes Sci Technol. 2010 Nov 1;4(6):1408-23. doi: 10.1177/193229681000400616.

Abstract

BACKGROUND

Insulin resistance is a significant risk factor in the pathogenesis of type 2 diabetes. This article presents pilot study results of the dynamic insulin sensitivity and secretion test (DISST), a high-resolution, low-intensity test to diagnose insulin sensitivity (IS) and characterize pancreatic insulin secretion in response to a (small) glucose challenge. This pilot study examines the effect of glucose and insulin dose on the DISST, and tests its repeatability.

METHODS

DISST tests were performed on 16 subjects randomly allocated to low (5 g glucose, 0.5 U insulin), medium (10 g glucose, 1 U insulin) and high dose (20 g glucose, 2 U insulin) protocols. Two or three tests were performed on each subject a few days apart.

RESULTS

Average variability in IS between low and medium dose was 10.3% (p=.50) and between medium and high dose 6.0% (p=.87). Geometric mean variability between tests was 6.0% (multiplicative standard deviation (MSD) 4.9%). Geometric mean variability in first phase endogenous insulin response was 6.8% (MSD 2.2%). Results were most consistent in subjects with low IS.

CONCLUSIONS

These findings suggest that DISST may be an easily performed dynamic test to quantify IS with high resolution, especially among those with reduced IS.

摘要

背景

胰岛素抵抗是2型糖尿病发病机制中的一个重要危险因素。本文介绍了动态胰岛素敏感性和分泌试验(DISST)的初步研究结果,这是一种高分辨率、低强度的试验,用于诊断胰岛素敏感性(IS)并描述胰腺对(小剂量)葡萄糖刺激的胰岛素分泌情况。这项初步研究考察了葡萄糖和胰岛素剂量对DISST的影响,并测试了其可重复性。

方法

对16名受试者进行DISST试验,这些受试者被随机分配到低剂量(5克葡萄糖,0.5单位胰岛素)、中剂量(10克葡萄糖,1单位胰岛素)和高剂量(20克葡萄糖,2单位胰岛素)方案组。在几天内对每个受试者进行两到三次试验。

结果

低剂量和中剂量之间IS的平均变异性为10.3%(p = 0.50),中剂量和高剂量之间为6.0%(p = 0.87)。各次试验之间的几何平均变异性为6.0%(乘性标准差(MSD)为4.9%)。第一阶段内源性胰岛素反应的几何平均变异性为6.8%(MSD为2.2%)。在IS较低的受试者中结果最为一致。

结论

这些发现表明,DISST可能是一种易于实施的动态试验,能够以高分辨率量化IS,尤其是在IS降低的人群中。

相似文献

3
A spectrum of dynamic insulin sensitivity test protocols.一系列动态胰岛素敏感性测试方案。
J Diabetes Sci Technol. 2011 Nov 1;5(6):1499-508. doi: 10.1177/193229681100500626.

引用本文的文献

3
Variability in Estimated Modelled Insulin Secretion.估算模型胰岛素分泌的变异性。
J Diabetes Sci Technol. 2022 May;16(3):732-741. doi: 10.1177/1932296821991120. Epub 2021 Feb 15.
4
6
Estimating Increased EGP During Stress Response in Critically Ill Patients.估算危重症患者应激反应时的 EGP 增加量。
J Diabetes Sci Technol. 2021 Jul;15(4):856-864. doi: 10.1177/1932296820922842. Epub 2020 Jun 1.
10
Evaluation of pharmacokinetic model designs for subcutaneous infusion of insulin aspart.门冬胰岛素皮下输注的药代动力学模型设计评估
J Pharmacokinet Pharmacodyn. 2017 Oct;44(5):477-489. doi: 10.1007/s10928-017-9535-z. Epub 2017 Aug 22.

本文引用的文献

3
Methods of measuring insulin sensitivity.测量胰岛素敏感性的方法。
Biol Res Nurs. 2007 Apr;8(4):305-18. doi: 10.1177/1099800406298775.
7
Intensive insulin therapy in the medical ICU.医学重症监护病房中的强化胰岛素治疗。
N Engl J Med. 2006 Feb 2;354(5):449-61. doi: 10.1056/NEJMoa052521.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验