Suppr超能文献

评价基于培养和 PCR 方法对人工接种 ground beef 中大肠杆菌 O157:H7 的检测。

Evaluation of culture- and PCR-based detection methods for Escherichia coli O157:H7 in inoculated ground beeft.

机构信息

U.S. Department of Agriculture, Agricultural Research Service, Roman L. Hruska U.S. Meat Animal Research Center, Clay Center, Nebraska 68933-0166, USA.

出版信息

J Food Prot. 2005 Aug;68(8):1566-74. doi: 10.4315/0362-028x-68.8.1566.

Abstract

Currently, several beef processors employ test-and-hold systems for increased quality control of ground beef. In such programs, each lot of product must be tested and found negative for Escherichia coli O157:H7 prior to release of the product into commerce. Optimization of three testing attributes (detection time, specificity, and sensitivity) is critical to the success of such strategies. Because ground beef is a highly perishable product, the testing methodology used must be as rapid as possible. The test also must have a low false-positive result rate so product is not needlessly discarded. False-negative results cannot be tolerated because they would allow contaminated product to be released and potentially cause disease. In this study, two culture-based and three PCR-based methods for detecting E. coli O157:H7 in ground beef were compared for their abilities to meet the above criteria. Ground beef samples were individually spiked with five genetically distinct strains of E. coli O157: H7 at concentrations of 17 and 1.7 CFU/65 g and then subjected to the various testing methodologies. There was no difference (P > 0.05) in the abilities of the PCR-based methods to detect E. coli O157:H7 inoculated in ground beef at 1.7 CFU/65 g. The culture-based systems detected more positive samples than did the PCR-based systems, but the detection times (21 to 48 h) were at least 9 h longer than those for the PCR-based methods (7.5 to 12 h). Ground beef samples were also spiked with potentially cross-reactive strains. The PCR-based systems that employed an immunomagnetic separation step prior to detection produced fewer false-positive results.

摘要

目前,一些牛肉加工商采用测试和保留系统来提高碎牛肉的质量控制水平。在这些计划中,在将产品投放市场之前,每批产品都必须经过测试,并且必须对大肠杆菌 O157:H7 呈阴性。优化三个测试属性(检测时间、特异性和灵敏度)对于此类策略的成功至关重要。由于碎牛肉是一种极易腐烂的产品,因此所用的测试方法必须尽可能快速。该测试还必须具有低假阳性结果率,以免不必要地丢弃产品。不能容忍假阴性结果,因为它们会允许受污染的产品放行并可能导致疾病。在这项研究中,比较了两种基于培养的和三种基于 PCR 的方法,用于检测碎牛肉中的大肠杆菌 O157:H7,以评估它们满足上述标准的能力。将五个具有不同遗传特征的大肠杆菌 O157:H7 菌株单独以 17 和 1.7 CFU/65 g 的浓度接种到碎牛肉中,然后对各种测试方法进行了测试。在以 1.7 CFU/65 g 接种到碎牛肉中的大肠杆菌 O157:H7 的检测能力方面,基于 PCR 的方法之间没有差异(P>0.05)。基于培养的系统检测到的阳性样本多于基于 PCR 的系统,但检测时间(21 至 48 小时)至少比基于 PCR 的方法长 9 小时(7.5 至 12 小时)。还在碎牛肉样品中混入了可能发生交叉反应的菌株。在检测前采用免疫磁分离步骤的基于 PCR 的系统产生的假阳性结果较少。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验