在SimSET中对块探测器进行建模。

Modeling block detectors in SimSET.

作者信息

Harrison Robert, Gillispie Steven, Schmitz Ruth, Lewellen Thomas

机构信息

Radiology, University of Washington, Seattle, Washington.

出版信息

J Nucl Med. 2008;49 Suppl 1:410P.

Abstract

OBJECTIVES

We have added a block detector model to the Simulation System for Emission Tomography (SimSET) software version 2.9. METHODS: The new model simulates the detector system as a collection of right rectangular boxes and allows for very flexible positioning of these boxes. This model allows users to simulate typical block-based cylindrical tomographs, pixelated positron emission mammography (PEM) detectors, and many more imaginative tomograph designs. We have tested the block detector software against analytically derived results and against SimSET simulations of dual-headed and cylindrical detector tomographs. We have also compared experimental and simulated sensitivities for a General Electric DSTE PET for 3 different phantom diameters in 2d and 3d acquisition modes. RESULTS: The tests against analytically derived results and against simulations were validated both statistically using the t-test and visually by comparing profiles through the sinograms. Within the limits of statistical fluctuation, the new software passed all tests. In comparisons with data from the PET scanner, the simulation showed better agreement than previous SimSET releases, but still showed substantially increased coincidence sensitivity. CONCLUSIONS: We believe the increased sensitivity is a result of the very simple default models used for energy resolution and scintillation light collection, and the lack of any livetime correction. The new release provides a user-modifiable function where all these factors can be realistically modeled for a given tomograph. The SimSET software, including source code, remains in the public domain.

摘要

目的

我们在发射断层扫描模拟系统(SimSET)软件版本2.9中添加了一个模块探测器模型。方法:新模型将探测器系统模拟为一组直角矩形盒,并允许对这些盒子进行非常灵活的定位。该模型允许用户模拟典型的基于模块的圆柱形断层扫描仪、像素化正电子发射乳腺断层摄影(PEM)探测器以及更多富有想象力的断层扫描仪设计。我们已将模块探测器软件与解析推导结果以及双头和圆柱形探测器断层扫描仪的SimSET模拟进行了对比测试。我们还比较了通用电气DSTE PET在2D和3D采集模式下针对3种不同体模直径的实验灵敏度和模拟灵敏度。结果:针对解析推导结果和模拟的测试,通过t检验进行了统计学验证,并通过比较正弦图的剖面图进行了直观验证。在统计波动范围内,新软件通过了所有测试。与PET扫描仪的数据相比,模拟结果比SimSET之前的版本显示出更好的一致性,但仍显示出符合灵敏度大幅提高。结论:我们认为灵敏度提高是由于用于能量分辨率和闪烁光收集的非常简单的默认模型,以及缺乏任何活时间校正。新版本提供了一个用户可修改的功能,在其中可以针对给定的断层扫描仪对所有这些因素进行实际建模。包括源代码在内的SimSET软件仍处于公共领域。

相似文献

3
Design and Implementation of a Block Detector Simulation in SimSET.SimSET 中块探测器模拟的设计与实现。
IEEE Nucl Sci Symp Conf Rec (1997). 2006;5:3151-3153. doi: 10.1109/NSSMIC.2006.356543.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验