Behrens Rolf
Physikalisch-Technische Bundesanstalt, Bundesallee 100, Braunschweig, Germany.
Radiat Prot Dosimetry. 2011 Nov;147(3):373-9. doi: 10.1093/rpd/ncq459. Epub 2010 Dec 14.
The International Organization for Standardization (ISO) has issued a standard series on photon reference radiation qualities (ISO 4037). In this work, conversion coefficients from air kerma to dose equivalent quantities not included in ISO 4037-3 are supplied for the following quantities: For H(p)(0.07) for X and gamma radiation qualities for the rod, the pillar and the slab phantom and for H(p)(3) for X and gamma radiation qualities for the slab phantom. In addition, an overview of conversion coefficients suggested for use for all quantities relevant in radiation protection is provided.
国际标准化组织(ISO)已发布了一系列关于光子参考辐射质量的标准(ISO 4037)。在本工作中,针对以下量提供了从空气比释动能到ISO 4037-3未包含的剂量当量量的转换系数:对于棒体、柱体和平板模体的X和γ辐射质量的H(p)(0.07),以及平板模体的X和γ辐射质量的H(p)(3)。此外,还提供了建议用于辐射防护中所有相关量的转换系数概述。