Abstract

For the purpose of radiation protection, ICRU Report 57/ICRP Publication 74 provides a list of monoenergetic conversion coefficients to be used with, among others, photon reference fields generated with X-ray tubes. A comprehensive definition of these photon reference fields can be found in international standard ISO 4037; however, it lacks thorough indication of the allowed deviations of essential parameters that influence these X-ray reference fields. These parameters are the high-voltage tube potential, the thickness of the beryllium window and the purity and thickness of the filter materials used to create different radiation qualities. Small variations of these parameters can lead to significant changes in the created X-ray spectra and, hence, the spectra-dependent conversion coefficients for phantom-related radiation-protection quantities. This can lead to situations in which the conversion coefficients listed in ISO 4037 cannot be used, resulting in time-consuming spectrometry measurements. In this work, the impact on the resulting conversion coefficients is investigated using a simplified mathematical approximation model. The findings are validated with an independent X-ray spectra calculation programme. As a result, well-founded upper limit values on the allowed deviations of the essential X-ray tube parameters are proposed to be used in a future revision of ISO 4037.

摘要

为了辐射防护的目的,国际辐射单位与测量委员会第57号报告/国际放射防护委员会第74号出版物提供了一份单能转换系数列表,该列表可用于多种情况,包括由X射线管产生的光子参考场。这些光子参考场的全面定义可在国际标准ISO 4037中找到;然而,它缺乏对影响这些X射线参考场的基本参数允许偏差的详细说明。这些参数包括管高压、铍窗厚度以及用于产生不同辐射品质的滤过材料的纯度和厚度。这些参数的微小变化可能会导致所产生的X射线能谱发生显著变化,进而导致与体模相关的辐射防护量的能谱依赖性转换系数发生变化。这可能会导致无法使用ISO 4037中列出的转换系数的情况,从而导致耗时的能谱测量。在这项工作中,使用简化的数学近似模型研究了对所得转换系数的影响。研究结果通过独立的X射线能谱计算程序进行了验证。结果,提出了关于基本X射线管参数允许偏差的有充分依据的上限值,以便在ISO 4037的未来修订中使用。

相似文献

1
Implications of X-ray tube parameter deviations in X-ray reference fields.X射线参考射野中X射线管参数偏差的影响
Radiat Prot Dosimetry. 2016 Feb;168(2):175-83. doi: 10.1093/rpd/ncv184. Epub 2015 Apr 17.

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验