Department of Glaucoma, Pushpagiri Eye Institute, 241, Uma Plaza, West Marredpally, Secunderabad, Andhra Pradesh, India.
Indian J Ophthalmol. 2011 Jan-Feb;59(1):23-7. doi: 10.4103/0301-4738.73716.
The aim was to study optic nerve head (ONH) parameters in normal Indian eyes using spectral domain optical coherence tomography (OCT)/scanning laser ophthamoscope (SLO).
One hundred and fifty-seven eyes of 157 normal subjects of various age groups underwent ONH imaging with spectral OCT/SLO and the parameters obtained were correlated with disc size. The effect of age, gender, and refractive error on various ONH parameters were also studied.
The mean optic disc area was 3.36 ± 0.64 mm 2 (range, 2.13-5.08 mm 2 ), mean rim area was 2.49 ± 0.58 mm 2 (range, 1.20-3.62 mm 2 ), and mean cup area was 1.10 ± 0.75 mm 2 (range, 0-3.07 mm 2 ). The disc area showed significant positive correlation with the rim area, cup area, horizontal cup disc ratio, vertical cup disc ratio, cup disc area ratio, mean cup depth, and maximum cup depth (P < 0.001). Neither gender nor refractive error showed any significant difference in various ONH parameters. ONH parameters did not show significant change with age except for rim area which declined with the advancing age (r = -0.25, P < 0.001).
The quantitative measurement of ONH topography obtained with this study provides a normative database for an Indian population with spectral OCT/SLO. As optic disc area influences ONH topography, disc size should to be considered when evaluating optic disc for progressive optic neuropathies such as glaucoma.
本研究旨在使用谱域光相干断层扫描(OCT)/扫频激光检眼镜(SLO)研究印度正常人眼的视神经头(ONH)参数。
对 157 例不同年龄组的 157 只正常眼进行 ONH 成像,采用谱 OCT/SLO,将获得的参数与视盘大小相关联。还研究了年龄、性别和屈光不正对各种 ONH 参数的影响。
平均视盘面积为 3.36 ± 0.64mm 2(范围:2.13-5.08mm 2),平均视盘边缘面积为 2.49 ± 0.58mm 2(范围:1.20-3.62mm 2),平均杯面积为 1.10 ± 0.75mm 2(范围:0-3.07mm 2)。视盘面积与视盘边缘面积、杯面积、水平杯盘比、垂直杯盘比、杯盘面积比、平均杯深度和最大杯深度呈显著正相关(P<0.001)。性别和屈光不正均未对视盘参数产生显著影响。除视盘边缘面积随年龄增加而减小外(r = -0.25,P<0.001),各种 ONH 参数在年龄上均无显著变化。