AIM

To establish a method for detection of plasma total homocysteine with HPLC.

METHODS

The chromatography analysis was carried out using a Symmetry Shield RP18. The mobile phase was sodium acetate (0.08 mol/L) and methanol (1%) and we utilized a HPLC system with fluorescence detection of plasma homocysteine derivatized from reaction with 7-fluorobenzo-2-oxa-1,3-diazole-4-sulphonate (SBD-F).

RESULTS

The average recoveries were 95.8 - 100.8% and the relative standard deviations were 1.2-2.0%.

CONCLUSION

The results showed it to be a rapid and accurate method for the determination of homocysteine level in plasma.

摘要

目的

建立一种用高效液相色谱法检测血浆总同型半胱氨酸的方法。

方法

使用Symmetry Shield RP18进行色谱分析。流动相为醋酸钠(0.08 mol/L)和甲醇(1%),我们采用了一种高效液相色谱系统,该系统通过荧光检测与7-氟苯并-2-恶唑-1,3-二氮杂萘-4-磺酸盐(SBD-F)反应衍生化的血浆同型半胱氨酸。

结果

平均回收率为95.8 - 100.8%,相对标准偏差为1.2 - 2.0%。

结论

结果表明该方法是测定血浆中同型半胱氨酸水平的一种快速、准确的方法。