Si Jiemin, Gu Baojun, Yu Jianjun, Xu Yuemin
Department of Urology, The Sixth People's Hospital, Shanghai Jiaotong University, Shanghai, China.
Photomed Laser Surg. 2011 Feb;29(2):105-7. doi: 10.1089/pho.2009.2748. Epub 2010 Dec 23.
To evaluate the safety and efficacy of the RevoLix 70W 2 micron continuous wave laser vaporesection in the treatment of high-risk patients with benign prostatic hyperplasia (BPH).
Forty-six high-risk patients (mean age, 82.6 y old) with BPH underwent 2-μm continuous wave laser vaporesection.
The operative time, drop in hemoglobin, drop in serum sodium, indwelling catheterization time, operative complications, international prostatic symptom scores (IPSS), quality of life (QoL), urinary flow rate (Qmax), and post voiding residual urine volume (PVR) were observed.
All 46 patients recovered without incident. The mean operative time was 68 ± 16.3 min. Occasional venous hemorrhage occurred during the operation, but no arterial hemorrhage was observed. Hemoglobin decreased from preoperative 15.0 g/dL to postoperative 14.3 g/dL, serum sodium decreased from preoperative 142.4 mmol/L to postoperative 141.6 mmol/L. IPSS decreased from preoperative 22 ± 6.2 to postoperative 9 ± 3.3, QoL scores decreased from 5.1 ± 0.7 to 2.1 ± 0.7, Qmax increased from 8.4 ± 5.2 to 21.2 ± 12.3 mL/sec, PVR decreased from 94.2 ± 60.2 to 21.6 ± 6.4 mL. The parameters were significantly different between pre- and postoperative results.
The RevoLix 70W 2-μm continuous wave laser vaporesection is safe and effective in the treatment of high-risk patients with BPH.
评估RevoLix 70W 2微米连续波激光汽化切除术治疗高危良性前列腺增生(BPH)患者的安全性和有效性。
46例高危BPH患者(平均年龄82.6岁)接受了2微米连续波激光汽化切除术。
观察手术时间、血红蛋白下降情况、血清钠下降情况、留置导尿时间、手术并发症、国际前列腺症状评分(IPSS)、生活质量(QoL)、尿流率(Qmax)和排尿后残余尿量(PVR)。
46例患者均顺利康复。平均手术时间为68±16.3分钟。手术过程中偶尔发生静脉出血,但未观察到动脉出血。血红蛋白从术前的15.0 g/dL降至术后的14.3 g/dL,血清钠从术前的142.4 mmol/L降至术后的141.6 mmol/L。IPSS从术前的22±6.2降至术后的9±3.3,QoL评分从5.1±0.7降至2.1±0.7,Qmax从8.4±5.2增至21.2±12.3 mL/秒,PVR从94.2±60.2降至21.6±6.4 mL。术前和术后结果的参数有显著差异。
RevoLix 70W 2微米连续波激光汽化切除术治疗高危BPH患者安全有效。