PURPOSE

To compare the adequacy of transjugular liver biopsy (TJLB) specimens with use of the 18-gauge Quick-Core and Flexcore needles.

MATERIALS AND METHODS

The records of 233 patients who underwent a TJLB procedure from January 2005 to December 2006 were retrospectively reviewed. Tissue samples from a total of 194 procedures were available for review; 117 TJLB procedures were performed with a Quick-Core needle and 77 were performed with a Flexcore needle. A single pathologist reviewed all the liver biopsy specimens in a blinded fashion. The χ(2), Fisher exact, and Student t tests were used to analyze differences between groups.

RESULTS

The TJLB procedure was technically successful in 232 of 233 cases (99.6%). Histologic diagnosis was possible in 96% of cases. Sample fragmentation rates were 24.9% with the Quick-Core needle and 14.3% with the Flexcore needle (P = .1). The mean numbers of complete portal tracts (CPTs) per submitted tissue per procedure were 10.0 ± 4.6 for the Quick-Core needle and 12.2 ± 6.1 for the Flexcore needle (P = .003). The mean numbers of CPTs per liver sample were 2.63 ± 1.8 for the Quick-Core needle and 3.28 ± 3.3 for the Flexcore needle (P = .00004). Complications were more common in patients with multiple comorbidities such as renal failure and coagulopathy and those who had received a liver transplant.

CONCLUSIONS

This study demonstrates that the 18-gauge Flexcore TJLB system provided better liver biopsy specimens compared with the 18-gauge Quick-Core needle system.

摘要

目的

比较使用 18 号快速活检枪和 FlexCore 活检针进行经颈静脉肝活检的组织标本的充分性。

材料与方法

回顾性分析 2005 年 1 月至 2006 年 12 月期间行经颈静脉肝活检术的 233 例患者的病历资料。共 194 例患者的肝活检组织标本可供评估,其中 117 例患者采用快速活检枪,77 例患者采用 FlexCore 活检针。由同一位病理医生对所有肝活检标本进行盲法评估。采用 χ(2)检验、Fisher 确切概率法检验和 t 检验进行统计学分析。

结果

233 例患者中行经颈静脉肝活检术的成功率为 232 例(99.6%)。96%的病例获得了组织学诊断。快速活检枪组标本碎片率为 24.9%,FlexCore 活检针组为 14.3%(P =.1)。快速活检枪组每例送检组织的完整门脉区(CPT)数为 10.0 ± 4.6 个,FlexCore 活检针组为 12.2 ± 6.1 个(P =.003)。快速活检枪组每例肝活检样本的 CPT 数为 2.63 ± 1.8 个,FlexCore 活检针组为 3.28 ± 3.3 个(P =.00004)。患有多种合并症(如肾衰竭和凝血障碍)和曾接受过肝移植的患者并发症更常见。

结论

本研究表明,与 18 号快速活检枪相比,18 号 FlexCore 经颈静脉肝活检系统提供了更好的肝活检标本。