Suppr超能文献

上颌尖牙的自锁托槽和传统托槽的内收。

Maxillary canine retraction with self-ligating and conventional brackets.

机构信息

Department of Orthodontics, Centro Universitário Franciscano, Santa Maria–RS, Brazil.

出版信息

Angle Orthod. 2011 Mar;81(2):292-7. doi: 10.2319/062510-348.1.

Abstract

OBJECTIVE

To measure space closure during the retraction of upper permanent canines with self-ligating and conventional brackets.

MATERIALS AND METHODS

Fifteen patients who required maxillary canine retraction into first premolar extraction sites as part of their orthodontic treatment completed this study. In a random split-mouth design, the retraction of upper canines was performed using an elastomeric chain with 150 g of force. The evaluations were performed in dental casts (T0, initial; T1, 4 weeks; T2, 8 weeks; T3, 12 weeks). The amount of movement and the rotation of the canines as well as anchorage loss of the upper first molars were evaluated.

RESULTS

There was no difference between self-ligating and conventional brackets regarding the distal movement of upper canines and mesial movement of first molars (P > .05). Rotation of the upper canines was minimized with self-ligating brackets (P < .05).

CONCLUSION

Distal movement of the upper canines and anchorage loss of the first molars were similar with both conventional and self-ligating brackets. Rotation of the upper canines during sliding mechanics was minimized with self-ligating brackets.

摘要

目的

测量上颌恒尖牙内收时的间隙关闭量,使用自锁托槽和传统托槽。

材料和方法

本研究纳入了 15 名需要上颌尖牙整体内收至第一前磨牙拔牙间隙的患者。采用随机分组的方法,使用 150g 橡皮圈对上颌尖牙进行内收。在牙模上进行评估(T0,初始;T1,4 周;T2,8 周;T3,12 周)。评估内容包括牙齿的移动量、牙齿的旋转以及上颌第一磨牙的支抗丧失。

结果

在尖牙远中移动和第一磨牙近中移动方面,自锁托槽和传统托槽之间没有差异(P>.05)。自锁托槽能最小化尖牙的旋转(P<.05)。

结论

在滑动机制中,自锁托槽能最小化尖牙的旋转,而尖牙的远中移动和第一磨牙的支抗丧失在传统托槽和自锁托槽之间相似。

相似文献

1
Maxillary canine retraction with self-ligating and conventional brackets.
Angle Orthod. 2011 Mar;81(2):292-7. doi: 10.2319/062510-348.1.
2
Canine retraction and anchorage loss: self-ligating versus conventional brackets in a randomized split-mouth study.
Angle Orthod. 2014 Sep;84(5):846-52. doi: 10.2319/100813-743.1. Epub 2014 Mar 4.
3
The Effect of Using Self-ligating Brackets on Maxillary Canine Retraction: A Split-mouth Design Randomized Controlled Trial.
J Contemp Dent Pract. 2016 Jun 1;17(6):496-503. doi: 10.5005/jp-journals-10024-1879.
5
Tooth movement rate and anchorage lost during canine retraction: .
Angle Orthod. 2019 Jul;89(4):559-565. doi: 10.2319/061318-443.1. Epub 2019 Feb 11.
8
Rate of tooth movement under heavy and light continuous orthodontic forces.
Am J Orthod Dentofacial Orthop. 2009 Aug;136(2):150.e1-9; discussion 150-1. doi: 10.1016/j.ajodo.2009.03.026.
9
Duration and anchorage management of canine retraction with bodily versus tipping mechanics.
Angle Orthod. 2008 Jan;78(1):95-100. doi: 10.2319/011707-24.1.

引用本文的文献

1
Rotational Control and Retraction of Maxillary Canine Using Self-Ligating Empower Brackets: An Study.
J Pharm Bioallied Sci. 2024 Jul;16(Suppl 3):S2072-S2074. doi: 10.4103/jpbs.jpbs_24_24. Epub 2024 May 1.
3
Implant-supported canine retraction using different reactivation intervals of elastomeric chains: A CBCT-based split-mouth randomized controlled trial.
Dental Press J Orthod. 2023 Nov 3;28(5):e2321166. doi: 10.1590/2177-6709.28.5.e2123166.oar. eCollection 2023.
4
Methods of measuring distal canine movement and rotation- A review.
J Orthod Sci. 2023 Apr 28;12:25. doi: 10.4103/jos.jos_82_22. eCollection 2023.
6
Response to the Letter.
Angle Orthod. 2022 May 1;92(3):427. doi: 10.2319/1945-7103-92.3.427.
7
A Novel Technique for Shortening Orthodontic Treatment: The "JET System".
Medicina (Kaunas). 2022 Jan 19;58(2):150. doi: 10.3390/medicina58020150.
8
The Tip and Torque adjustable bracket as a new concept in design.
Angle Orthod. 2022 May 1;92(3):380-387. doi: 10.2319/061421-474.1.
10
Evaluating the Efficacy of a Modified Piezo-Puncture Method on the Rate of Tooth Movement in Orthodontic Patients: A Clinical Study.
Turk J Orthod. 2020 Mar 1;33(1):13-20. doi: 10.5152/TurkJOrthod.2020.19013. eCollection 2020 Mar.

本文引用的文献

1
In-vivo studies offer best measure of self-ligation.
Am J Orthod Dentofacial Orthop. 2009 Aug;136(2):141-2. doi: 10.1016/j.ajodo.2009.06.006.
3
Comparison of rate of canine retraction with conventional molar anchorage and titanium implant anchorage.
Am J Orthod Dentofacial Orthop. 2008 Jul;134(1):30-5. doi: 10.1016/j.ajodo.2006.05.044.
4
Factors influencing efficiency of sliding mechanics to close extraction space: a systematic review.
Orthod Craniofac Res. 2008 May;11(2):65-73. doi: 10.1111/j.1601-6343.2008.00421.x.
5
Duration and anchorage management of canine retraction with bodily versus tipping mechanics.
Angle Orthod. 2008 Jan;78(1):95-100. doi: 10.2319/011707-24.1.
6
Clinical evaluation of a low-friction attachment device during canine retraction.
Angle Orthod. 2007 Nov;77(6):968-72. doi: 10.2319/102706-443.1.
8
Self-ligating vs conventional twin brackets during en-masse space closure with sliding mechanics.
Am J Orthod Dentofacial Orthop. 2007 Aug;132(2):223-5. doi: 10.1016/j.ajodo.2007.04.028.
9
Self-ligating brackets: present and future.
Am J Orthod Dentofacial Orthop. 2007 Aug;132(2):216-22. doi: 10.1016/j.ajodo.2006.06.018.
10
A comparison of different ligation methods on friction.
Am J Orthod Dentofacial Orthop. 2006 Nov;130(5):666-70. doi: 10.1016/j.ajodo.2006.04.021.

文献AI研究员