Suppr超能文献

使用自结扎Empower托槽对上颌尖牙进行旋转控制和内收:一项研究。

Rotational Control and Retraction of Maxillary Canine Using Self-Ligating Empower Brackets: An Study.

作者信息

Alla Ramya, Chandrika P Sindhu, Ronanki Susanthi, Duddu Yesuratnam, Shalini G N, Naziya Sheik

机构信息

Assistant Professor, Department of Orthodontics and Dentofacial Orthopedic, Government Dental College and Hospital, Vijayawada, Andhra Pradesh, India.

Assistant Professor, Department of Public Health Dentistry, Government Dental College and Hospital Kadapa, Andhra Pradesh, India.

出版信息

J Pharm Bioallied Sci. 2024 Jul;16(Suppl 3):S2072-S2074. doi: 10.4103/jpbs.jpbs_24_24. Epub 2024 May 1.

Abstract

INTRODUCTION

Interest in self-ligating brackets is generally smoother and more comfortable.

OBJECTIVES

To compare rate of retraction and rotational control of maxillary canines with self-ligating MBT brackets on one side and conventional MBT brackets on the other side of the maxillary arch.

MATERIALS AND METHODS

Ten subjects with a mean age range of 18 to 25 years were selected. For each patient in the maxillary arch, bonding was performed with 0.022-inch slot conventional MBT brackets on one side and 0.022-inch slot self-ligating MBT brackets on the other side. Stainless steel 0.009-inch ligatures are used for conventional ligation. Retraction of canines was performed with 0.019 × 0.025-inch stainless steel wires using NiTi closed coil springs with eyelets of 12 mm and 9 mm. The force of retraction was measured using a dynamometer. Dental casts were made at each time interval to record the canine retraction rate (in mm) and rotation (in degrees).

RESULTS

The mean difference in the retraction rate was 0.045 mm/month between self-ligating and conventional brackets, respectively ( > 0.05). The mean difference of total rotation of canines with self-ligating and conventional brackets was 1.5°, which gives evidence that there was less rotation of canines with self-ligating brackets.

CONCLUSION

There was no statistically significant difference in canine retraction rates between conventional and self-ligating brackets. Secure ligation with the self-ligating brackets showed better rotational control than the conventional brackets.

摘要

引言

对自锁托槽的兴趣通常在于其更顺滑且更舒适。

目的

比较在上颌牙弓一侧使用自锁MBT托槽,另一侧使用传统MBT托槽时上颌尖牙的内收速率和旋转控制情况。

材料与方法

选取10名平均年龄在18至25岁之间的受试者。对于上颌牙弓中的每位患者,一侧使用0.022英寸槽沟的传统MBT托槽,另一侧使用0.022英寸槽沟的自锁MBT托槽进行粘结。使用0.009英寸的不锈钢结扎丝进行传统结扎。使用带有12毫米和9毫米小孔的镍钛闭合螺旋弹簧,通过0.019×0.025英寸的不锈钢丝进行尖牙内收。使用测力计测量内收力。在每个时间间隔制作牙模,以记录尖牙的内收速率(以毫米为单位)和旋转(以度为单位)。

结果

自锁托槽和传统托槽的内收速率平均差异分别为0.045毫米/月(>0.05)。自锁托槽和传统托槽的尖牙总旋转平均差异为1.5°,这表明自锁托槽的尖牙旋转较少。

结论

传统托槽和自锁托槽在尖牙内收速率上无统计学显著差异。自锁托槽的牢固结扎显示出比传统托槽更好的旋转控制。