Suppr超能文献

Influence of variation of etching conditions on the sensitivity of PADC detectors with a new evaluation method.

作者信息

Fiechtner-Scharrer A, Mayer S, Boschung M, Whitelaw A

机构信息

Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.

出版信息

Radiat Prot Dosimetry. 2011 Mar;144(1-4):150-4. doi: 10.1093/rpd/ncq558. Epub 2011 Jan 6.

Abstract

At the Paul Scherrer Institut, a personal neutron dosimetry system based on chemically etched poly allyl diglycol carbonate (PADC) detectors and an automatic track counting (Autoscan 60) for neutron dose evaluations has been in routine use since 1998. Today, the hardware and the software of the Autoscan 60 are out of date, no spare components are available anymore and more sophisticated image-analysis systems are already developed. Therefore, a new evaluation system, the 'TASLIMAGE', was tested thoroughly in 2009 for linearity, reproducibility, influence of etching conditions and so forth, with the intention of replacing the Autoscan 60 in routine evaluations. The TASLIMAGE system is based on a microscope (high-quality Nikon optics) and an ultra-fast three-axis motorised control for scanning the detectors. In this paper, the TASLIMAGE system and its possibilities for neutron dose calculation are explained in more detail and the study of the influence of the variation of etching conditions on the sensitivity and background of the PADC detectors is described. The etching temperature and etching duration were varied, which showed that the etching conditions do not have a significant influence on the results of non-irradiated detectors. However, the sensitivity of irradiated detectors decreases by 5 % per 1°C when increasing the etching temperature. For the variation of the etching duration, the influence on the sensitivity of irradiated detectors is less pronounced.

摘要

相似文献

1
Influence of variation of etching conditions on the sensitivity of PADC detectors with a new evaluation method.
Radiat Prot Dosimetry. 2011 Mar;144(1-4):150-4. doi: 10.1093/rpd/ncq558. Epub 2011 Jan 6.
2
COMPARISON OF DIFFERENT PADC MATERIALS AND ETCHING CONDITIONS FOR FAST NEUTRON DOSIMETRY.
Radiat Prot Dosimetry. 2016 Sep;170(1-4):162-7. doi: 10.1093/rpd/ncv421. Epub 2015 Oct 5.
3
Comparison of different PADC materials for neutron dosimetry.
Radiat Prot Dosimetry. 2014 Oct;161(1-4):104-7. doi: 10.1093/rpd/nct241. Epub 2013 Oct 3.
4
Determination of the response function for two personal neutron dosemeter designs based on PADC.
Radiat Prot Dosimetry. 2014 Oct;161(1-4):82-5. doi: 10.1093/rpd/nct256. Epub 2013 Oct 31.
5
The ENEA neutron personal dosimetry service.
Radiat Prot Dosimetry. 2006;120(1-4):312-5. doi: 10.1093/rpd/nci567. Epub 2006 Apr 27.
6
Progress report of the CR-39 neutron personal monitoring service at PSI.
Radiat Prot Dosimetry. 2007;125(1-4):237-40. doi: 10.1093/rpd/ncl114. Epub 2006 Oct 12.
7
COMPARISON OF PADC NEUTRON DETECTORS FROM DIFFERENT SUPPLIERS.
Radiat Prot Dosimetry. 2018 Aug 1;180(1-4):196-200. doi: 10.1093/rpd/ncx193.
8
Novel Al2O3:C,Mg fluorescent nuclear track detectors for passive neutron dosimetry.
Radiat Prot Dosimetry. 2007;126(1-4):278-83. doi: 10.1093/rpd/ncm058. Epub 2007 May 23.
9
HIGH DOSE FAST NEUTRON DOSIMETRY USING PADC PLASTIC NUCLEAR TRACK DETECTORS AND GREY LEVEL ANALYSIS.
Radiat Prot Dosimetry. 2018 Aug 1;180(1-4):220-224. doi: 10.1093/rpd/ncx186.
10
Performance of a PADC personal neutron dosemeter at simulated and real workplace fields of the nuclear industry.
Radiat Prot Dosimetry. 2007;126(1-4):314-7. doi: 10.1093/rpd/ncm065. Epub 2007 Jun 19.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验