Suppr超能文献

骨水泥型和非骨水泥型定制股骨假体周围及非骨水泥髋臼杯的早期假体周围骨重塑。

Early periprosthetic bone remodelling around cemented and uncemented custom-made femoral components and their uncemented acetabular cups.

机构信息

Department of Orthopaedics, University Hospital Leuven, K.U. Leuven, Campus Pellenberg, Weligerveld 1, 3212 Lubbeek, Belgium.

出版信息

Arch Orthop Trauma Surg. 2011 Jul;131(7):941-8. doi: 10.1007/s00402-010-1239-4. Epub 2011 Jan 19.

Abstract

INTRODUCTION

Periprosthetic bone remodelling after total hip replacement may contribute to aseptic loosening of the prosthesis. The selection between cemented and uncemented fixation of the stem is mainly determined by patient's age, general constitution and CT scan-estimated bone quality; intra-operative observation may ultimately influence the choice of the fixation method. The influence of cemented versus uncemented stem fixation on periprosthetic bone remodelling around the uncemented cup has, to our knowledge, never been studied until now.

METHODS

A total of 75 patients received intra-operatively manufactured stem prostheses and a standard hydroxy apatite-coated pinnacle cup. The pre-operative CT scans provides guidance for the bone quality and hence the type of stem fixation: cemented or uncemented. The influence of either type of stem fixation on periprosthetic bone remodelling around the cup and the stem was measured by bone mineral density at 6 weeks, and 3, 6 and 12 months after surgery.

RESULTS

Early changes in bone mineral density were noted. The type of stem fixation had an influence on the bone remodelling of the femur and also of the pelvis. The caudal part of the acetabulum was subject to a greater loss in BMD at 12 months in the group with cemented stem fixation. Changes at 12 months correlated with the changes measured at any time point.

CONCLUSIONS

The selection of the stem implant and its type of fixation in the femoral cavity (cemented or uncemented fixation) seems to have an impact on the bone mineral density of the acetabulum. Long-term clinical follow-up is required to draw conclusions regarding the influence on prosthesis survival.

摘要

简介

全髋关节置换术后的假体周围骨重塑可能导致假体无菌性松动。柄的骨水泥固定与非骨水泥固定的选择主要取决于患者的年龄、一般体质和 CT 扫描估计的骨质量;术中观察最终可能会影响固定方法的选择。迄今为止,我们从未研究过骨水泥固定与非骨水泥固定对非骨水泥髋臼杯周围假体周围骨重塑的影响。

方法

总共 75 名患者接受了术中制造的假体和标准的羟基磷灰石涂层髋臼杯。术前 CT 扫描为骨质量提供指导,从而指导选择骨水泥固定或非骨水泥固定的类型。通过术后 6 周、3 个月、6 个月和 12 个月的骨密度测量,评估两种类型的柄固定对杯和柄周围假体周围骨重塑的影响。

结果

早期发现骨密度的变化。柄固定的类型对股骨和骨盆的骨重塑都有影响。在骨水泥固定组中,髋臼的尾侧部分在 12 个月时的骨密度丢失更大。12 个月时的变化与任何时间点测量的变化相关。

结论

股骨髓腔中柄植入物的选择及其固定类型(骨水泥固定或非骨水泥固定)似乎对髋臼的骨密度有影响。需要长期的临床随访来得出关于假体生存影响的结论。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验