Suppr超能文献

三尖瓣瓣膜支架植入术:新型自扩张超吸水性聚合物支架。

Tricuspid valved stent implantation: novel stent with a self-expandable super-absorbent polymer.

机构信息

Department of Cardiovascular Surgery, University Hospital Schleswig-Holstein, Campus Kiel, Kiel, Germany.

出版信息

Eur J Cardiothorac Surg. 2011 Aug;40(2):503-7. doi: 10.1016/j.ejcts.2010.11.051. Epub 2011 Jan 19.

Abstract

OBJECTIVE

Trans-catheter aortic and pulmonary valve replacement procedures can result in favorable outcomes in selected patients. The aim of this study was to investigate the functioning of a novel self-expanding valved stent with super-absorbent polymer (SAP) for minimally invasive replacement of the tricuspid valve.

METHODS

A newly designed nitinol stent with SAP was specially designed for the tricuspid annulus. This device was composed of right atrial anchoring elements, a left ventricular tubular stent, and a trileaflet bovine pericardial valve. The stent was coated with a waterproof material, and a pouch containing SAP for minimizing paravalvular leakage was placed beneath the atrial element. Seven pigs underwent minimally invasive off-pump tricuspid valved stent implantation. This was performed through a lower ministernotomy using a transventricular approach under transesophageal echocardiographic guidance. After 1 and 6h, a complete echocardiographic evaluation and hemodynamics (Swan-Ganz catheter) were performed.

RESULTS

Six of seven pigs exhibited normal hemodynamics immediately after tricuspid valved stent implantation and maintained stability for the entire period of monitoring. In one pig, a part of the atrial stent elements was deployed into the right ventricle, leading to significant paravalvular leakage, and died very soon. All subsequent animals survived with good results in the observation period. Accurate positioning of the valved stent was documented in six of seven pigs. SAP expanded and filled the gap between the stent and the native annulus in all animals. Mild paravalvular leakage was found in two of the six animals. Nevertheless, the observed leakage decreased to trace levels 6h after implantation. In the additional four pigs, only trace tricuspid regurgitation was revealed. No right ventricular outflow tract obstruction was detected.

CONCLUSIONS

Trans-apical off-pump tricuspid valved stent implantation is feasible in an acute experimental setting, and SAP may help to reduce paravalvular leakages.

摘要

目的

经导管主动脉瓣和肺动脉瓣置换术可在选定的患者中产生有利的结果。本研究的目的是研究一种新型的自膨式带超吸水性聚合物(SAP)的瓣膜支架,用于微创二尖瓣置换术。

方法

专门为三尖瓣环设计了一种新型的带 SAP 的镍钛诺支架。该装置由右心房锚固元件、左心室管状支架和三叶牛心包瓣组成。支架涂有防水材料,心房元件下方放置一个装有 SAP 的袋,以减少瓣周漏。7 头猪接受微创非体外循环三尖瓣带瓣支架植入术。在食管超声心动图引导下,通过经心室入路,经下小开胸术进行。术后 1h 和 6h 行完全超声心动图评估和血流动力学(Swan-Ganz 导管)检查。

结果

7 头猪中有 6 头在植入三尖瓣带瓣支架后立即表现出正常的血流动力学,并在整个监测期间保持稳定。在一头猪中,部分心房支架元件被部署到右心室,导致严重的瓣周漏,并很快死亡。所有后续动物在观察期内均存活,结果良好。在 7 头猪中有 6 头,瓣膜支架的定位准确。SAP 在所有动物中均扩张并填充支架与天然瓣环之间的间隙。6 只动物中有 2 只发现轻度瓣周漏。然而,植入后 6h 观察到的漏出量减少至微量。在另外 4 头猪中,仅发现微量三尖瓣反流。未发现右心室流出道梗阻。

结论

经心尖非体外循环三尖瓣带瓣支架植入术在急性实验环境中是可行的,SAP 可能有助于减少瓣周漏。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验