To assess short-term survival after transcatheter mitral valve replacement using a unique mitral valved stent design and anchoring system.
The new nitinol self-expandable valved stent houses a trileaflet glutaraldehyde-preserved bioprosthesis and contains atrial and ventricular fixation systems. Eight pigs underwent transesophageal echocardiogram-guided transapical mitral valved stent implantation through a lower mini-sternotomy. Intracardiac pressure gradients were estimated by transesophageal echocardiogram.
The mean mitral annulus size was 24.6 +/- 1.4 mm, and the valved stent size was 26.0 +/- 2.6 mm. The average mean transvalvular gradient across the valved stent immediately after deployment, at 6 hours, and after 1 week remained low. The gradient across the neighboring left ventricular outflow tract was not affected. Average animal survival was 7.3 days (8 hours to 29 days). Animals that died before 1 week (n = 4) were found at necropsy to have valved stent malpositioning. Animals that survived 1 week or more had accurate deployment and only trace post-deployment paravalvular leak. The causes of death in this latter group were endocarditis (n = 1), failure of atrial fixation (n = 2), and failure of ventricular fixation (n = 1). There was no valved stent embolization in any of the animals.
Adequate function and effective anchoring of the new mitral valved stent allowed for short-term animal survival after transapical mitral valved stent implantation.
评估使用独特的二尖瓣瓣膜支架设计和锚固系统进行经导管二尖瓣置换后的短期生存率。
新型镍钛诺自膨式瓣膜支架内置三叶戊二醛保存的生物瓣,并包含心房和心室固定系统。通过小胸骨下段经食管超声心动图引导,8 只猪接受经心尖二尖瓣瓣膜支架植入术。通过经食管超声心动图估计心内压力梯度。
二尖瓣瓣环平均大小为 24.6±1.4mm,瓣膜支架大小为 26.0±2.6mm。支架瓣膜植入后即刻、6 小时和 1 周的平均跨瓣梯度均较低。邻近左心室流出道的平均梯度不受影响。平均动物存活率为 7.3 天(8 小时至 29 天)。在 1 周内死亡的动物(n=4)尸检时发现支架瓣膜位置不当。存活 1 周或更长时间的动物支架瓣膜定位准确,仅微量瓣周漏。后一组动物的死亡原因分别为心内膜炎(n=1)、心房固定失败(n=2)和心室固定失败(n=1)。在任何动物中均未发生瓣膜支架栓塞。
新型二尖瓣瓣膜支架的充分功能和有效锚固允许经心尖二尖瓣瓣膜支架植入后短期动物生存。