Putz P, Coussaert E, Delvaux D, Long Pretz P, Thys R, Cantraine F
Service de Chirurgie Orthopédique, Hôpital Universitaire Brugmann, Bruxelles, Belgique.
Int Orthop. 1990;14(3):285-92. doi: 10.1007/BF00178761.
A series of 1871 lesions of the upper end of the femur were treated in 32 hospitals in Belgium using a dynamic hip screw. Unstable pertrochanteric fractures were present in 34.4%. The remainder were intracapsular, extracapsular and subtrochanteric fractures, or tumour deposits. The patients were elderly, infirm and usually female. A fortnight after operation 89% were sitting, 64% could walk with a frame and 31% with crutches. Failure of fixation occurred in 3.6% of cases overall, with 6.6% in unstable fractures. Perioperative screw compression did not appear helpful, since most fractures settled after operation.
比利时32家医院使用动力髋螺钉治疗了1871例股骨上端损伤。34.4%为不稳定型转子间骨折。其余为囊内、囊外和转子下骨折或肿瘤沉积物。患者多为老年、体弱,且通常为女性。术后两周,89%的患者能坐起,64%的患者可借助助行架行走,31%的患者可借助拐杖行走。总体固定失败率为3.6%,不稳定骨折的固定失败率为6.6%。围手术期螺钉加压似乎并无帮助,因为大多数骨折术后均已复位。