Suppr超能文献

一种临床摄影测量法,用于测量牙弓尺寸和近远中牙齿尺寸。

A clinical photogrammetric method to measure dental arch dimensions and mesio-distal tooth size.

机构信息

Department of Orthodontics, Federal University of Pará, Belém, Pará, Brazil.

出版信息

Eur J Orthod. 2011 Dec;33(6):721-6. doi: 10.1093/ejo/cjq149. Epub 2011 Jan 31.

Abstract

The aim of this research was to evaluate the reliability and validity of measurements obtained from clinical standardized occlusal photographs compared with dental cast measurements. This study comprised a consecutive sample of 16 patients (eight males and eight females, aged 15-24 years) in the permanent dentition without agenesis and/or tooth loss. A paired t-test and intraclass correlation coefficient (ICC) were used to examine validity and reliability. Both statistics were applied for intra- and inter-methods error analysis, at P < 0.05. Random error for the photogrammetric method (less than 0.48 mm) was similar to that for the dental cast measurements (less than 0.43 mm). ICC revealed excellent reliability for both methods (P < 0.01) and no significant difference for any variables, with the exception of upper inter-canine width obtained on the dental casts (P = 0.0038) and photogrammetry (P = 0.01). However, differences were less than 1 per cent of the mean inter-canine width. Inter-method analysis showed a significant correlation for all variables (P < 0.001), with good to excellent reliability (r = 0.66-0.93). A significant mean inter-method difference was consistently observed for the upper first molars (0.33 mm, P < 0.01). For the remaining teeth (left to right second premolars), the largest mean difference was approximately equal to the resolution of the human eye (0.2 mm or less). Minor differences (around 2 per cent of the mean) and an excellent ICC (0.75-0.93, P < 0.01) were observed for arch dimensions. Except for the mesio-distal width of the upper first molars, the recently developed photogrammetric method showed accuracy, validity, and reliability acceptable for clinical and scientific purposes.

摘要

本研究旨在评估临床标准化咬合照片测量值与牙模测量值的可靠性和有效性。本研究纳入了 16 名连续患者(8 名男性和 8 名女性,年龄 15-24 岁),均为恒牙列,无先天缺失和/或牙齿缺失。采用配对 t 检验和组内相关系数(ICC)检验有效性和可靠性。两种统计方法均应用于内和方法间误差分析,P<0.05。摄影测量法的随机误差(小于 0.48mm)与牙模测量法的随机误差(小于 0.43mm)相似。ICC 显示两种方法均具有极好的可靠性(P<0.01),且除了牙模测量的上中切牙宽度(P=0.0038)和摄影测量的上中切牙宽度(P=0.01)外,其他变量间均无显著差异。然而,差异小于中切牙宽度的平均值的 1%。组间分析显示所有变量均具有显著相关性(P<0.001),且具有良好到极好的可靠性(r=0.66-0.93)。上第一磨牙始终存在显著的平均组间差异(0.33mm,P<0.01)。对于其余牙齿(左侧至右侧第二前磨牙),最大的平均差异约等于人眼的分辨率(0.2mm 或更小)。对于牙弓尺寸,观察到了较小的差异(约为平均值的 2%)和极好的 ICC(0.75-0.93,P<0.01)。除了上第一磨牙的近远中宽度外,新开发的摄影测量法具有临床和科学目的所需的准确性、有效性和可靠性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验