Suppr超能文献

采用两种磺基萘酚染料,在无提取的分光光度法测定药物制剂和人尿中掺假曲马多,基于离子对反应。

Use of two sulfonthalein dyes in the extraction-free spectrophotometric assay of tramadol in dosage forms and in spiked human urine based on ion-pair reaction.

机构信息

Department of Chemistry, Manasagangothri, University of Mysore, Mysore 570 006, Karnataka, India.

出版信息

Drug Test Anal. 2012 Feb;4(2):116-22. doi: 10.1002/dta.247. Epub 2011 Feb 3.

Abstract

Tramadol is a centrally acting analgesic used in the prevention and treatment of moderate to severe pain. Two sensitive, selective, and rapid spectrophotometric methods are described for the determination of tramadol in its dosage forms and in spiked human urine. The methods are based on formation of yellow ion-pairs between tramadol and two sulfonthalein dyes; bromocresol purple (BCP) and bromocresol green (BCG) in dichloromethane medium followed by absorbance measurement at 400 and 410 nm, respectively. Under the optimum conditions, tramadol could be assayed in the concentration ranges, 1-15 and 1-16 µg ml(-1) with correlation coefficient greater than 0.999 in both cases. The molar absorptivity values are calculated to be 1.84 × 10(4) and 1.97 × 10(4) l mol(-1) cm(-1) for BCP and BCG methods, respectively; and the corresponding Sandell sensitivity values are 0.0143 and 0.0134 µg cm(-2). The limits of detection (LOD) and quantification (LOQ) have also been reported. The stoichiometry of the reaction was found to be 1:1 in both cases and the conditional stability constant (K(f)) values of the ion pairs have been calculated. The within-day and between-day RSD were 0.9-1.96% and 1.56-3.21%, respectively. The methods were successfully applied to the determination of tramadol in tablets and injections and also in spiked human urine with good recoveries. The procedures are simple, accurate, and suitable for quality control application.

摘要

曲马多是一种中枢作用的镇痛药,用于预防和治疗中度至重度疼痛。本文介绍了两种灵敏、选择性和快速的分光光度法,用于测定其制剂和加标人尿中的曲马多。该方法基于曲马多与两种磺基萘酚染料(溴甲酚紫(BCP)和溴甲酚绿(BCG))在二氯甲烷介质中形成黄色离子对,然后分别在 400nm 和 410nm 处测定吸光度。在最佳条件下,曲马多的浓度范围为 1-15μg/ml 和 1-16μg/ml,两种情况下的相关系数均大于 0.999。摩尔吸光系数值分别计算为 BCP 和 BCG 方法的 1.84×10(4)和 1.97×10(4)l/mol/cm(1);相应的桑德尔灵敏度值分别为 0.0143 和 0.0134μg/cm(2)。还报告了检测限(LOD)和定量限(LOQ)。发现两种情况下反应的化学计量比均为 1:1,并计算了离子对的条件稳定常数(K(f))值。日内和日间 RSD 分别为 0.9-1.96%和 1.56-3.21%。该方法成功应用于片剂和注射液中曲马多的测定以及加标人尿中的测定,回收率良好。该程序简单、准确,适用于质量控制应用。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验