J Chromatogr A. 2011 Apr 29;1218(17):2451-9. doi: 10.1016/j.chroma.2011.01.032. Epub 2011 Jan 19.
Adenovirus type 3 dodecahedric virus-like particles (Ad3 VLP) are an interesting delivery vector. They penetrate animal cells in culture very efficiently and up to 300,000 Ad3 VLP can be observed in one cell. The purification of such particles usually consists of several steps. In these work we describe the method development and optimization for the purification of Ad3 VLP using the Convective Interaction Media analytical columns (CIMac). Results obtained with the CIMac were compared to the already established two-step purification protocol for Ad3 VLP based on sucrose density gradient ultracentifugation and the Q-Sepharose ion-exchange column. Pure, concentrated and bioactive VLP were obtained and characterized by several analytical methods. The recovery of the Ad3 VLP was more than 50% and the purified fraction was almost completely depleted of DNA; less than 1% of DNA was present. The purification protocol was shortened from five days to one day and remarkably high penetration efficacy of the CIMac-purified vector was retained. Additionally, CIMac QA analytical column has proven to be applicable for the final and in-process control of various Ad3 VLP samples.
腺病毒 3 型十二面体病毒样颗粒(Ad3 VLP)是一种很有趣的递呈载体。它们能非常有效地穿透培养的动物细胞,在一个细胞中可观察到多达 30 万个 Ad3 VLP。此类颗粒的纯化通常包括多个步骤。在这项工作中,我们描述了使用流变相分离介质分析柱(CIMac)纯化 Ad3 VLP 的方法开发和优化。用 CIMac 获得的结果与基于蔗糖密度梯度超速离心和 Q-琼脂糖离子交换柱的 Ad3 VLP 两步法纯化方案进行了比较。通过几种分析方法获得了纯的、浓缩的、有生物活性的 VLP,并对其进行了表征。Ad3 VLP 的回收率超过 50%,且纯化部分几乎完全不含 DNA;仅存在不到 1%的 DNA。该纯化方案已从五天缩短至一天,并且保留了 CIMac 纯化载体的高穿透效率。此外,CIMac QA 分析柱已被证明适用于各种 Ad3 VLP 样品的最终和过程控制。