Vitamin D deficiency in an infant is associated with a wide range of adverse health outcomes in later life. A method for the quantification of 25-hydroxyvitamin D(3) [25(OH)D(3), the best-established indicator of vitamin D status] in neonatal dried blood spots (DBSs) using LC/ESI-MS/MS has been developed and validated. The method employed two steps of derivatization, a Diels-Alder reaction with 4-phenyl-1,2,4-triazoline-3,5-dione followed by acetylation, to enhance the detectability of 25(OH)D(3) in ESI-MS/MS and to separate 25(OH)D(3) from 3-epi-25-hydroxyvitamin D(3) [3-epi-25(OH)D(3)], a potent interfering metabolite. 25(OH)D(3) was extracted from two DBS punches (3  mm in diameter, equivalent to 5.3  μL of whole blood), purified using an Oasis HLB(®) cartridge, and subjected to derivatization prior to analysis with LC/ESI-MS/MS. 25-Hydroxyvitamin D(4) was used as the internal standard. This method was reproducible (intra- and inter-assay RSDs, <6.9%) and accurate (analytical recovery, 95.2-102.7%), and the LOQ was 3.0  ng/mL. The developed method enabled specific quantification of 25(OH)D(3) in neonatal DBSs and detection of vitamin D deficiency without interference from 3-epi-25(OH)D(3).

摘要

婴儿维生素 D 缺乏与日后生活中广泛的不良健康后果有关。本研究开发并验证了一种利用 LC/ESI-MS/MS 定量检测新生儿干血斑(DBS)中 25-羟维生素 D(3)[25(OH)D(3]的方法,这是评估维生素 D 状态的最佳指标。该方法采用两步衍生化反应,先用 4-苯-1,2,4-三唑啉-3,5-二酮进行 Diels-Alder 反应,然后进行乙酰化,以提高 25(OH)D(3)在 ESI-MS/MS 中的检测能力,并将 25(OH)D(3)与 3-差向-25-羟维生素 D(3)[3-差向-25(OH)D(3]分离,后者是一种具有很强干扰作用的代谢物。从两个 DBS 血斑(直径 3 毫米,相当于 5.3 μL 全血)中提取 25(OH)D(3),用 Oasis HLB(®)小柱纯化,衍生化后用 LC/ESI-MS/MS 进行分析。25-羟维生素 D(4)作为内标。该方法重复性好(批内和批间 RSD 均<6.9%),准确度高(分析回收率为 95.2-102.7%),定量下限为 3.0ng/mL。该方法可特异性定量检测新生儿 DBS 中的 25(OH)D(3),并可在无 3-差向-25(OH)D(3)干扰的情况下检测维生素 D 缺乏。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验